A platform for research: civil engineering, architecture and urbanism
Enhancing load capacity of reinforced concrete columns using high strength concrete and fiber reinforcement
Strengthening of structural elements is sometimes necessary for architectural purposes to withstand additional loads without cross-section enlargement. This study evaluates the structural performance of reinforced concrete columns toughened using high-strength concrete, steel fiber concrete of 1% volume fraction, and near-surface mounted NSM steel or carbon fiber reinforced polymer CFRP bars. Five columns of 0.15×0.15×1 m were cast and axially loaded till failure. The investigational consequences revealed that a load-carrying capacity and stiffness augmented by 55.1 and 91.1% when the compressive strength is 1.5 times the normal with a ductility decrease of 28.2% whereas steel fiber concrete raised them by 34.3, 6.4, and 11.6%. In addition, NSM steel or CFRP bars exhibited ultimate loads and stiffness 13.6 to 29.7% and 17.2 to 21.7% higher than the non-strengthened column. However, the ductility decreased by 2.5 to 12.4%.
Enhancing load capacity of reinforced concrete columns using high strength concrete and fiber reinforcement
Strengthening of structural elements is sometimes necessary for architectural purposes to withstand additional loads without cross-section enlargement. This study evaluates the structural performance of reinforced concrete columns toughened using high-strength concrete, steel fiber concrete of 1% volume fraction, and near-surface mounted NSM steel or carbon fiber reinforced polymer CFRP bars. Five columns of 0.15×0.15×1 m were cast and axially loaded till failure. The investigational consequences revealed that a load-carrying capacity and stiffness augmented by 55.1 and 91.1% when the compressive strength is 1.5 times the normal with a ductility decrease of 28.2% whereas steel fiber concrete raised them by 34.3, 6.4, and 11.6%. In addition, NSM steel or CFRP bars exhibited ultimate loads and stiffness 13.6 to 29.7% and 17.2 to 21.7% higher than the non-strengthened column. However, the ductility decreased by 2.5 to 12.4%.
Enhancing load capacity of reinforced concrete columns using high strength concrete and fiber reinforcement
Ali, Shaima Sabri (author) / Hassoon, Alaa (author) / Abbas, Hajer Satih (author) / Albassam, Bassam Farman (author)
2024-09-18
doi:10.37868/sei.v6i2.id350
Sustainable Engineering and Innovation; Vol. 6 No. 2 (2024); 177-184 ; 2712-0562 ; 10.37868/sei.v6i2
Article (Journal)
Electronic Resource
English
Lateral Load Behavior of High Strength Fiber Reinforced Concrete Columns
British Library Conference Proceedings | 1996
|Reinforcement of prismatic concrete columns using fiber reinforced plastics
British Library Conference Proceedings | 2001
|Reinforcement of prismatic concrete columns using fiber reinforced polymers
British Library Conference Proceedings | 2007
|