A platform for research: civil engineering, architecture and urbanism
Noxious gases in rabbit housing systems: Effects of cross and longitudinal ventilation
Animal welfare is a matter of increasing interest due to ethical and economical worries regarding animal rights and the sustainability of meat production. Ammonia, carbon dioxide, and methane can be produced in the livestock buildings and, if not adequately controlled by ventilation, can be dangerous for animals and farmers. The aim of the present paper is to study the effects of different ventilation systems in rabbit buildings based on the temporal patterns and the spatial distribution of these noxious gases. The experimental measurements were conducted in two rabbit farms with genetically homogeneous animals subjected to the same diet. Two buildings with different forced ventilation layouts (cross ventilation building A and longitudinal ventilation building B) were subjected to the monitoring of indoor environmental conditions (temperature, relative humidity, ammonia, carbon dioxide, methane) over a whole year. In both the buildings, ventilation was adjusted automatically by means of electronic control units, which were controlled by temperature sensors, located at the centre of the buildings. Gas concentrations inside the buildings followed clearly defined sinusoidal patterns on a daily basis with the highest values reached in winter during the morning hours for ammonia and during the night hours for carbon dioxide and methane. In particular, ammonia revealed a maximum concentration of 30.7 mg m-3 in building A (cross ventilation) and 12.9 mg m-3 in building B (longitudinal ventilation), whereas the minimum values were 6.0 and 4.2 mg m-3, in building A and B, respectively. As a consequence, daily mean concentrations of noxious gases, solely could not be considered representative of the actual conditions of air quality in the buildings. The airflow direction clearly influenced the spatial concentration of ammonia, which showed different patterns in the two buildings. In building A, the highest ammonia concentration was in a diffuse central area, whereas in building B, it was determined to be less extended and ...
Noxious gases in rabbit housing systems: Effects of cross and longitudinal ventilation
Animal welfare is a matter of increasing interest due to ethical and economical worries regarding animal rights and the sustainability of meat production. Ammonia, carbon dioxide, and methane can be produced in the livestock buildings and, if not adequately controlled by ventilation, can be dangerous for animals and farmers. The aim of the present paper is to study the effects of different ventilation systems in rabbit buildings based on the temporal patterns and the spatial distribution of these noxious gases. The experimental measurements were conducted in two rabbit farms with genetically homogeneous animals subjected to the same diet. Two buildings with different forced ventilation layouts (cross ventilation building A and longitudinal ventilation building B) were subjected to the monitoring of indoor environmental conditions (temperature, relative humidity, ammonia, carbon dioxide, methane) over a whole year. In both the buildings, ventilation was adjusted automatically by means of electronic control units, which were controlled by temperature sensors, located at the centre of the buildings. Gas concentrations inside the buildings followed clearly defined sinusoidal patterns on a daily basis with the highest values reached in winter during the morning hours for ammonia and during the night hours for carbon dioxide and methane. In particular, ammonia revealed a maximum concentration of 30.7 mg m-3 in building A (cross ventilation) and 12.9 mg m-3 in building B (longitudinal ventilation), whereas the minimum values were 6.0 and 4.2 mg m-3, in building A and B, respectively. As a consequence, daily mean concentrations of noxious gases, solely could not be considered representative of the actual conditions of air quality in the buildings. The airflow direction clearly influenced the spatial concentration of ammonia, which showed different patterns in the two buildings. In building A, the highest ammonia concentration was in a diffuse central area, whereas in building B, it was determined to be less extended and ...
Noxious gases in rabbit housing systems: Effects of cross and longitudinal ventilation
DA BORSO, Francesco (author) / CHIUMENTI, Alessandro (author) / Mezzadri, Marco (author) / TERI, Francesco (author) / DA BORSO, Francesco / Chiumenti, Alessandro / Mezzadri, Marco / Teri, Francesco
2016-01-01
Article (Journal)
Electronic Resource
English
DDC:
690
Permissible limits of toxic and noxious gases in mine and tunnel ventilation
Engineering Index Backfile | 1926
|SWEDEN - Dry low emission process limits impact from noxious gases
Online Contents | 2005
NTIS | 1982
Whole Housing Ventilation Strategies