A platform for research: civil engineering, architecture and urbanism
Behavior of prestressing steels after fire
Even if a fire does not give rise to apparent damage in a prestressed structure, mechanical properties of materials as well as load distribution can be affected. A verification of residual load bearing capacity after fire is necessary to determine if the structure can be maintained in use. Mechanical properties of structural steels at high temperatures have been extensively studied. However, no attention has been paid to the behavior of steel wires after fire. This paper seeks to give a simplified estimation of the non-visible fire-induced damages produced in steel wires, with the hope that this information can be useful for engineers in the structural evaluation after a fire. Two aspects should be considered when assessing the security of the structures: The reduction of the prestressing loads due to the increment in the stress relaxation losses during the exposure to high temperatures and the permanent damage of the residual mechanical properties of steel wires produced by the fire.
Behavior of prestressing steels after fire
Even if a fire does not give rise to apparent damage in a prestressed structure, mechanical properties of materials as well as load distribution can be affected. A verification of residual load bearing capacity after fire is necessary to determine if the structure can be maintained in use. Mechanical properties of structural steels at high temperatures have been extensively studied. However, no attention has been paid to the behavior of steel wires after fire. This paper seeks to give a simplified estimation of the non-visible fire-induced damages produced in steel wires, with the hope that this information can be useful for engineers in the structural evaluation after a fire. Two aspects should be considered when assessing the security of the structures: The reduction of the prestressing loads due to the increment in the stress relaxation losses during the exposure to high temperatures and the permanent damage of the residual mechanical properties of steel wires produced by the fire.
Behavior of prestressing steels after fire
Atienza Riera, José Miguel (author) / Elices Calafat, Manuel (author)
2008-01-01
17th Congress of IABSE : creating and renewing urban structures, tall buildings, bridges and infrastructure | 17th Congress of IABSE : creating and renewing urban structures | 17/09/2008-19/09/2008 | Chicago, EEUU
Conference paper
Electronic Resource
English
DDC:
690
Behavior of Prestressing Steels After Fire
British Library Conference Proceedings | 2008
|Behavior of prestressing steels after a simulated fire: Fire-induced damages
Online Contents | 2009
|Behavior of prestressing steels after a simulated fire: Fire-induced damages
Online Contents | 2009
|Behavior of prestressing steels after a simulated fire: Fire-induced damages
British Library Online Contents | 2009
|