A platform for research: civil engineering, architecture and urbanism
Determination of bond model for 7-wire strands in pretensioned concrete beam
A correct choice of a bond model for prestressing tendons is crucial for the right modelling of a structural behaviour of a pretensioned concrete structure. The aim of this paper is the determination of an optimal bond model for 7-wire strands in a prestressed concrete beam produced in a precast concrete plant of Consolis Poland. ATENA 3D is used to develop finite element models of the beam that differ only in a bond stress-slip relationship of tendons. The bond stress-slip relationships for modelling are taken from the results of bond tests carried out by different researchers in previous years. Moreover, for comparison purposes, a simplified 2D model of the beam is created in Autodesk Robot. The strain distribution at the time of the strand release is found for each of the finite element models. The determined strain distributions are compared with the strain distribution in the beam established by an experimental test using a measuring system based on a digital image correlation. On the basis of the comparison results, the most appropriate bond models for 7-wire strands used in the beam are identified.
Determination of bond model for 7-wire strands in pretensioned concrete beam
A correct choice of a bond model for prestressing tendons is crucial for the right modelling of a structural behaviour of a pretensioned concrete structure. The aim of this paper is the determination of an optimal bond model for 7-wire strands in a prestressed concrete beam produced in a precast concrete plant of Consolis Poland. ATENA 3D is used to develop finite element models of the beam that differ only in a bond stress-slip relationship of tendons. The bond stress-slip relationships for modelling are taken from the results of bond tests carried out by different researchers in previous years. Moreover, for comparison purposes, a simplified 2D model of the beam is created in Autodesk Robot. The strain distribution at the time of the strand release is found for each of the finite element models. The determined strain distributions are compared with the strain distribution in the beam established by an experimental test using a measuring system based on a digital image correlation. On the basis of the comparison results, the most appropriate bond models for 7-wire strands used in the beam are identified.
Determination of bond model for 7-wire strands in pretensioned concrete beam
Parkhats, Vadzim (author) / Krzywoń, Rafał (author) / Hulimka, Jacek (author) / Kubica, Jan (author)
2021-12-31
Acta Polytechnica; Vol 61 No 6 (2021); 740-748 ; Acta Polytechnica; Vol. 61 No. 6 (2021); 740-748 ; 1805-2363 ; 1210-2709
Article (Journal)
Electronic Resource
English
DDC:
690
Bond of Pretensioned Strands in Fire Exposed Concrete
British Library Conference Proceedings | 2002
|Bond strength of pretensioned strands in SCC
Tema Archive | 2007
|Bond of 13mm prestressing steel strands in pretensioned concrete members
Online Contents | 2012
|Bond strength of pretensioned strands in SCC
British Library Conference Proceedings | 2007
|Bond of 13mm prestressing steel strands in pretensioned concrete members
Elsevier | 2012
|