A platform for research: civil engineering, architecture and urbanism
Full scale tests of the base-isolation system for an emergency hospital
The paper presents the results of some full-scale tests regarding the base-isolation system of the emergency room building of the polyclinic hospital in Palermo (Italy). This building has been recently realized and its base isolation system is characterized by double friction pendulum isolators. Static lateral pushing tests were aimed at identifying fundamental mechanical properties of the whole isolation level (e.g. friction forces and stiffness) in order to verify the agreement with the design hypotheses. Further dynamic tests provided different displacements of the isolated base followed by the instantaneous release (snap-back tests), in order to verify the effectiveness, the mechanical parameter in dynamics and re-centering capacity of the isolation system. The design of both the types of test and the respective results and interpretations are illustrated in the paper highlighting a number of issues arising when arranging such kind of investigations on full scale buildings.
Full scale tests of the base-isolation system for an emergency hospital
The paper presents the results of some full-scale tests regarding the base-isolation system of the emergency room building of the polyclinic hospital in Palermo (Italy). This building has been recently realized and its base isolation system is characterized by double friction pendulum isolators. Static lateral pushing tests were aimed at identifying fundamental mechanical properties of the whole isolation level (e.g. friction forces and stiffness) in order to verify the agreement with the design hypotheses. Further dynamic tests provided different displacements of the isolated base followed by the instantaneous release (snap-back tests), in order to verify the effectiveness, the mechanical parameter in dynamics and re-centering capacity of the isolation system. The design of both the types of test and the respective results and interpretations are illustrated in the paper highlighting a number of issues arising when arranging such kind of investigations on full scale buildings.
Full scale tests of the base-isolation system for an emergency hospital
Ferrotto, M. F. (author) / Cavaleri, L. (author) / Di Trapani, F. (author) / Castaldo, P. (author)
2019-01-01
Conference paper
Electronic Resource
English
Base Isolation System to Be Tested on Full-Scale Bridges
ASCE | 2016
|Validations of Anisotropic Aggregate Base Behavior from Full-Scale Pavement Tests
British Library Conference Proceedings | 2009
|PVP2002-1453 Shaking Table Tests of Full Scale Base-Isolated Structures
British Library Conference Proceedings | 2002
|