A platform for research: civil engineering, architecture and urbanism
Numerical Analysis Effect of Home Roof Design Towards Thermal Comfort of Occupants
The cool room temperature is a requirement in the thermal comfort of a building. In earthquake prone areas, building structures should be designed with minimal material weight. Therefore, it is necessary to be aware of an alternative solution to ensure the room's thermal comfort with minimal weight. This research aims to analyze the influence of roof slope 15O, 20O, 25O, 30O, 35O, 40O, and 45Oon the comfort of the room and the strength of the building in the house measuring 6 meters x 8 meters x 3 meters. Analysis is done with three software that is SketchUp as a design, CONTAM to analyze air pressure and TRNSYS to simulate all the data that has been created in SketchUp and CONTAM. Obtained the lowest temperature at a roof slope of 45Oand the lowest weight is the roof with a 15Oslope. Temperatur ruangan yang sejuk merupakan syarat dalam kenyamanan termal sebuah bangunan. Di kawasan rawan gempa, struktur bangunan harus dirancang dengan bobot material yang minimal. Oleh karena itu, perlu dicarikan solusi alternatif untuk menjamin kenyaman termal ruangan dengan bobot yang minimal. Penelitian ini bertujuan menganalisa pengaruh kemiringan atap 15o, 20o, 25o, 30o, 35o, 40o, dan 45oterhadap kenyamanan ruangan serta kekuatan bangunan pada rumah berukuran 6 meter x 8 meter x 3 meter. Analisa dilakukan dengan tigasoftwareyaituSketchUpsebagai perancangan,CONTAMuntuk menganalisa tekanan udara sertaTRNSYSuntuk menyimulasikan semua data yang telah di buat padaSketchUpdanCONTAM. Didapatkan hasil suhu terendah berada pada kemiringan atap 45odan bobot terendah adalah atap dengan kemiringan 15o.
Numerical Analysis Effect of Home Roof Design Towards Thermal Comfort of Occupants
The cool room temperature is a requirement in the thermal comfort of a building. In earthquake prone areas, building structures should be designed with minimal material weight. Therefore, it is necessary to be aware of an alternative solution to ensure the room's thermal comfort with minimal weight. This research aims to analyze the influence of roof slope 15O, 20O, 25O, 30O, 35O, 40O, and 45Oon the comfort of the room and the strength of the building in the house measuring 6 meters x 8 meters x 3 meters. Analysis is done with three software that is SketchUp as a design, CONTAM to analyze air pressure and TRNSYS to simulate all the data that has been created in SketchUp and CONTAM. Obtained the lowest temperature at a roof slope of 45Oand the lowest weight is the roof with a 15Oslope. Temperatur ruangan yang sejuk merupakan syarat dalam kenyamanan termal sebuah bangunan. Di kawasan rawan gempa, struktur bangunan harus dirancang dengan bobot material yang minimal. Oleh karena itu, perlu dicarikan solusi alternatif untuk menjamin kenyaman termal ruangan dengan bobot yang minimal. Penelitian ini bertujuan menganalisa pengaruh kemiringan atap 15o, 20o, 25o, 30o, 35o, 40o, dan 45oterhadap kenyamanan ruangan serta kekuatan bangunan pada rumah berukuran 6 meter x 8 meter x 3 meter. Analisa dilakukan dengan tigasoftwareyaituSketchUpsebagai perancangan,CONTAMuntuk menganalisa tekanan udara sertaTRNSYSuntuk menyimulasikan semua data yang telah di buat padaSketchUpdanCONTAM. Didapatkan hasil suhu terendah berada pada kemiringan atap 45odan bobot terendah adalah atap dengan kemiringan 15o.
Numerical Analysis Effect of Home Roof Design Towards Thermal Comfort of Occupants
Juliadi, Denda Afri (author) / Lapisa, Remon (author) / Purwantono, Purwantono (author) / Nurdin, Hendri (author)
2020-05-01
doi:10.46574/motivection.v2i2.54
MOTIVECTION : Journal of Mechanical, Electrical and Industrial Engineering; Vol 2 No 2 (2020): Motivection : Journal of Mechanical, Electrical and Industrial Engineering; 9-18 ; 2685-2098 ; 2655-7215
Article (Journal)
Electronic Resource
English
DDC:
690
Activity rates and thermal comfort of office occupants in Sydney
British Library Conference Proceedings | 2001
|