A platform for research: civil engineering, architecture and urbanism
State Opera House - upgrading: Case studies: earthquake risk buildings
The Local Government Act allows local bodies to take powers requiring building owners to upgrade masonry buildings to a reasonable level of seismic capacity. The State Opera House is one such building. The theatre was built in 1913 and allows for seating for 1300 patrons on three levels. The building is of brick construction with walls up to 685mm thick and 23,000mm high without intermediate support. Although the Wellington City Council generally requires buildings to achieve two thirds of the standard laid down by NZS 1900 Chap. 8:1965 the City Engineer requested that the Opera House be upgraded to full compliance with that standard. As a preliminary to detail design, tests were made on brick beam samples to determine what quality of brickwork existed within the building and what levels of stress could be reliably used in panel configurations. From these tests we determined a bond strength of 0.1MPa in mortar joints and F’c (Brick) 10MPa. This investigation was coupled with an extensive structural survey to supplement the meagre amound of information from drawings and original specification.
State Opera House - upgrading: Case studies: earthquake risk buildings
The Local Government Act allows local bodies to take powers requiring building owners to upgrade masonry buildings to a reasonable level of seismic capacity. The State Opera House is one such building. The theatre was built in 1913 and allows for seating for 1300 patrons on three levels. The building is of brick construction with walls up to 685mm thick and 23,000mm high without intermediate support. Although the Wellington City Council generally requires buildings to achieve two thirds of the standard laid down by NZS 1900 Chap. 8:1965 the City Engineer requested that the Opera House be upgraded to full compliance with that standard. As a preliminary to detail design, tests were made on brick beam samples to determine what quality of brickwork existed within the building and what levels of stress could be reliably used in panel configurations. From these tests we determined a bond strength of 0.1MPa in mortar joints and F’c (Brick) 10MPa. This investigation was coupled with an extensive structural survey to supplement the meagre amound of information from drawings and original specification.
State Opera House - upgrading: Case studies: earthquake risk buildings
Christianson, John (author)
1983-06-30
doi:10.5459/bnzsee.16.2.175-178
Bulletin of the New Zealand Society for Earthquake Engineering; Vol. 16 No. 2 (1983); 175-178 ; 2324-1543 ; 1174-9857
Article (Journal)
Electronic Resource
English
Upgrading seismic resistance of buildings for moderate earthquake risk
Elsevier | 1983
|Cashfields shopping centre: Christchurch: Case studies: earthquake risk buildings
BASE | 1983
|Upgrading earthquake resistance of existing steel frame buildings
British Library Conference Proceedings | 1995
|