Investigation of volatile organic compound (VOC) emission in oil terminal storage tank parks ; Lakiųjų organinių junginių (LOJ) emisijos tyrimas naftos terminalo talpyklų parkuose
The problem of VOC volatilization into the atmosphere from oil terminals is discussed in the paper. Investigation of VOC concentration in an oil terminal was performed in characterized spots of the main pollutant concentration – in storage tank parks of light and heavy oil products. A complex analysis of the impact of meteorological elements, oilproduct- storage tank construction, the level of filling storage tanks with oil products on the emissions of VOCs in oil terminals and adjacent territories is provided in the paper. The dependence of VOC concentration on the following parameters of the construction of storage tanks was analysed: the capacity of storage tanks, the insulation between the wall of a storage tank and peculiarities of the pontoon construction (single, double, triple insulation). The results of the investigation may be applied for the development and improvement of the VOC calculation method (LAND 31-2007/M-11), reduction of VOC emissions in the existing oil terminals and when developing new ones.
Investigation of volatile organic compound (VOC) emission in oil terminal storage tank parks ; Lakiųjų organinių junginių (LOJ) emisijos tyrimas naftos terminalo talpyklų parkuose
The problem of VOC volatilization into the atmosphere from oil terminals is discussed in the paper. Investigation of VOC concentration in an oil terminal was performed in characterized spots of the main pollutant concentration – in storage tank parks of light and heavy oil products. A complex analysis of the impact of meteorological elements, oilproduct- storage tank construction, the level of filling storage tanks with oil products on the emissions of VOCs in oil terminals and adjacent territories is provided in the paper. The dependence of VOC concentration on the following parameters of the construction of storage tanks was analysed: the capacity of storage tanks, the insulation between the wall of a storage tank and peculiarities of the pontoon construction (single, double, triple insulation). The results of the investigation may be applied for the development and improvement of the VOC calculation method (LAND 31-2007/M-11), reduction of VOC emissions in the existing oil terminals and when developing new ones.
Investigation of volatile organic compound (VOC) emission in oil terminal storage tank parks ; Lakiųjų organinių junginių (LOJ) emisijos tyrimas naftos terminalo talpyklų parkuose
Paulauskienė, Tatjana (author) / Zabukas, Vytenis (author) / Vaitiekūnas, Petras (author)
2009-01-01
Journal of environmental engineering and landscape management, Vilnius : Technika, 2009, vol. 17, no. 2, p. 81-88 ; ISSN 1648-6897 ; eISSN 1822-4199
Article (Journal)
Electronic Resource
Lithuanian , English