RE-BUILDING STRUCTURE PLAN REVIEW DORM REGIONAL PUSDIKLAT BUKITTINGGI
The study was conducted using the study of literature in which the calculations are performed withthe fourth floor of the building and guided by books and regulations or standards exist, where thedata were obtained from existing planning data is then compared with the count of writers. The finaldesign shows how to implement the planned building structural system for areas that have a strongseismic zoning and designed by Indonesian earthquake SNI 03-1726-2002 Rules and Procedures forConcrete structural Design for Buildings Buildings SNI 03-2847-2002. The assumptions used are 4-dimensional portal with vertical loading with horizontal shear forces and to calculate the forcesacting on the structure of the computer program used.This building structures using reinforced concrete construction starts from the upper structure(beams, columns and plates) and the bottom structure (foundation) with the quality of concrete fc '=20 MPa and using quality steel quality steel fy = 400 MPa, for plate thickness of 120 mm using theeach floor with reinforcement Ø10 used. Main reinforcement for the beams are O16 and Ø8 Ø19stirrups and reinforcement to the column while the main reinforcement is reinforcement Ø19 andØ10 stirrups. The foundation used is a drill foundation pile with a diameter of 80 cm and a depth of1320 cm foundation. The results of calculations for reinforcement on the author less for beams,plates and columns, compared with the results of existing planners.Keywords: bukittinggi, building structures, seismic load, dimension.
RE-BUILDING STRUCTURE PLAN REVIEW DORM REGIONAL PUSDIKLAT BUKITTINGGI
The study was conducted using the study of literature in which the calculations are performed withthe fourth floor of the building and guided by books and regulations or standards exist, where thedata were obtained from existing planning data is then compared with the count of writers. The finaldesign shows how to implement the planned building structural system for areas that have a strongseismic zoning and designed by Indonesian earthquake SNI 03-1726-2002 Rules and Procedures forConcrete structural Design for Buildings Buildings SNI 03-2847-2002. The assumptions used are 4-dimensional portal with vertical loading with horizontal shear forces and to calculate the forcesacting on the structure of the computer program used.This building structures using reinforced concrete construction starts from the upper structure(beams, columns and plates) and the bottom structure (foundation) with the quality of concrete fc '=20 MPa and using quality steel quality steel fy = 400 MPa, for plate thickness of 120 mm using theeach floor with reinforcement Ø10 used. Main reinforcement for the beams are O16 and Ø8 Ø19stirrups and reinforcement to the column while the main reinforcement is reinforcement Ø19 andØ10 stirrups. The foundation used is a drill foundation pile with a diameter of 80 cm and a depth of1320 cm foundation. The results of calculations for reinforcement on the author less for beams,plates and columns, compared with the results of existing planners.Keywords: bukittinggi, building structures, seismic load, dimension.
RE-BUILDING STRUCTURE PLAN REVIEW DORM REGIONAL PUSDIKLAT BUKITTINGGI
Edison, Roza (author) / Warman, Hendri (author) / Khadavi, Khadavi (author)
2013-09-10
Abstract of Undergraduate Research, Faculty of Civil and Planning Engineering, Bung Hatta University; Vol. 2 No. 2 (2013): Jurnal Jurusan Teknik Sipil UBH ; JURNAL TEKNIK SIPIL DAN PERENCANAAN; Vol 2 No 2 (2013): Jurnal Jurusan Teknik Sipil UBH
Article (Journal)
Electronic Resource
English
DDC:
690
Online Contents | 2008
Faculty Dorm of SMC (China) Ltd
British Library Online Contents | 1998
|