A platform for research: civil engineering, architecture and urbanism
Building Performance under Untypical Weather Conditions: A 40-Year Study of Hong Kong
As a common engineering practice, the buildings are usually evaluated under the Typical Meteorological Year (TMY), which represents the common weather situation. The warm and cool conditions, however, can affect the building performance considerably, yet building performances under such conditions cannot fully be given by the conventional TMY. This paper gives approaches to constructing the weather data that represents several warm and cool conditions and compares their differences by studying the cumulative cooling demands of a typical building in a hot and humid climate. Apart from the Extreme Weather Year (EWY), the Near-Extreme Weather Year (NEWY) and Common warm/cool Years (CY) data are proposed according to the occurrence distributions of the weather over the long term. It was found that the cooling demands of NEWY and EWY differ by 4.8% from the cooling needs of TMY. The difference between the cooling demands of NEWY and CY for most calendar months can be 20% and 15%, respectively. For the hot months, the cooling demands under NEWY and CY take 7.4–11.6% and 2.3–5.6% differences from those under TMY. The uncertainties of building performance due to the ever-changing weather conditions can be essential to the robustness of building performance evaluations.
Building Performance under Untypical Weather Conditions: A 40-Year Study of Hong Kong
As a common engineering practice, the buildings are usually evaluated under the Typical Meteorological Year (TMY), which represents the common weather situation. The warm and cool conditions, however, can affect the building performance considerably, yet building performances under such conditions cannot fully be given by the conventional TMY. This paper gives approaches to constructing the weather data that represents several warm and cool conditions and compares their differences by studying the cumulative cooling demands of a typical building in a hot and humid climate. Apart from the Extreme Weather Year (EWY), the Near-Extreme Weather Year (NEWY) and Common warm/cool Years (CY) data are proposed according to the occurrence distributions of the weather over the long term. It was found that the cooling demands of NEWY and EWY differ by 4.8% from the cooling needs of TMY. The difference between the cooling demands of NEWY and CY for most calendar months can be 20% and 15%, respectively. For the hot months, the cooling demands under NEWY and CY take 7.4–11.6% and 2.3–5.6% differences from those under TMY. The uncertainties of building performance due to the ever-changing weather conditions can be essential to the robustness of building performance evaluations.
Building Performance under Untypical Weather Conditions: A 40-Year Study of Hong Kong
Siwei Lou (author) / Zhengjie Peng (author) / Jilong Cai (author) / Yukai Zou (author) / Yu Huang (author)
2023
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Untypical steel arch - wind load
British Library Conference Proceedings | 2006
|Typical Meteorological Year for Building Energy Simulation in Hong Kong
Taylor & Francis Verlag | 1997
|Building Hong Kong : environmental considerations
TIBKAT | 2000
|