A platform for research: civil engineering, architecture and urbanism
Analysis of Longitudinal Timber Beam Joints Loaded with Simple Bending
The joints in timber structures are often the decisive factor in determining the load-bearing capacity, rigidity, sustainability, and durability of timber structures. Compared with the fasteners used for steel and concrete structures, fasteners for timber structures generally have a lower load-bearing capacity and rigidity, with the exception of glued joints. Glued joints in timber structures constitute a diverse group of rigid joints which are distinguished by sudden failure when the joint’s load-bearing capacity is reached. In this contribution, the load-bearing capacity of a longitudinal joint for a beam under simple flexural stress is analyzed using glued, double-sided splices. Joints with double-sided splices and connecting screws were also tested to compare the load-bearing capacity and rigidity. A third series of tests was carried out on joints made using glued double-sided splices augmented with screws. The aim of this combined joint was to ensure greater ductility after the load-bearing capacity of the glued splice joint had been reached.
Analysis of Longitudinal Timber Beam Joints Loaded with Simple Bending
The joints in timber structures are often the decisive factor in determining the load-bearing capacity, rigidity, sustainability, and durability of timber structures. Compared with the fasteners used for steel and concrete structures, fasteners for timber structures generally have a lower load-bearing capacity and rigidity, with the exception of glued joints. Glued joints in timber structures constitute a diverse group of rigid joints which are distinguished by sudden failure when the joint’s load-bearing capacity is reached. In this contribution, the load-bearing capacity of a longitudinal joint for a beam under simple flexural stress is analyzed using glued, double-sided splices. Joints with double-sided splices and connecting screws were also tested to compare the load-bearing capacity and rigidity. A third series of tests was carried out on joints made using glued double-sided splices augmented with screws. The aim of this combined joint was to ensure greater ductility after the load-bearing capacity of the glued splice joint had been reached.
Analysis of Longitudinal Timber Beam Joints Loaded with Simple Bending
Kristyna Vavrusova (author) / Antonin Lokaj (author) / David Mikolasek (author) / Oldrich Sucharda (author)
2020
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Behaviour Analysis of Axially Loaded Glued-in Timber-Steel Joints
British Library Conference Proceedings | 2001
|Bending Stiffness of Stress-Laminated Timber Decks with Butt Joints.
Online Contents | 1993
|Bending Stiffness of Stress-Laminated Timber Decks with Butt Joints
British Library Online Contents | 1993
|