Evaluation of HVAC Design Parameters in High-Performance Hospital Operating Theatres
Unidirectional flow air-conditioning systems are suitable for achieving indoor air quality required in high-performance operating rooms (organ transplants, cardiac surgery, aorta, orthopedic, burns, etc.). This paper analyzes indoor environmental conditions and technical and hygienic requirements for the design of heating, ventilation, and air-Conditioning (HVAC) systems for high-performance operating theatres. The main standards applicable to this type of operating rooms were compiled. Standard UNE 100713:2015, ASHRAE Standard 170-2017, and the European pre-norm EN 16244 were analyzed. A case study shows the lack of uniformity in design criteria and their ranges of values, which generates different design approaches. It was concluded that using these standards applicable to high-performance operating rooms leads to very different indoor environmental conditions for patients and medical personnel—air velocity profiles, air movement pattern, temperature, relative humidity gradients, and pressure stratification. Computational fluid dynamics (CFD) studies have been shown to detect areas of haven that favor microbiological load accumulation. In this way, it is possible to define cleaning protocols to attend these anomalies in a preventive way.
Evaluation of HVAC Design Parameters in High-Performance Hospital Operating Theatres
Unidirectional flow air-conditioning systems are suitable for achieving indoor air quality required in high-performance operating rooms (organ transplants, cardiac surgery, aorta, orthopedic, burns, etc.). This paper analyzes indoor environmental conditions and technical and hygienic requirements for the design of heating, ventilation, and air-Conditioning (HVAC) systems for high-performance operating theatres. The main standards applicable to this type of operating rooms were compiled. Standard UNE 100713:2015, ASHRAE Standard 170-2017, and the European pre-norm EN 16244 were analyzed. A case study shows the lack of uniformity in design criteria and their ranges of values, which generates different design approaches. It was concluded that using these standards applicable to high-performance operating rooms leads to very different indoor environmental conditions for patients and medical personnel—air velocity profiles, air movement pattern, temperature, relative humidity gradients, and pressure stratification. Computational fluid dynamics (CFD) studies have been shown to detect areas of haven that favor microbiological load accumulation. In this way, it is possible to define cleaning protocols to attend these anomalies in a preventive way.
Evaluation of HVAC Design Parameters in High-Performance Hospital Operating Theatres
Gonzalo Sánchez-Barroso (author) / Justo García Sanz-Calcedo (author)
2019
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
HVAC Systems' Design in Hospitals Operating Theatres: Comfort, Air Quality, and Energy
British Library Conference Proceedings | 2004
|Computers . Operating theatres
Online Contents | 1994
Gas Chromatographic Determination of Halothane Levels in Hospital Operating Theatres
Online Contents | 2003
|Gas Chromatographic Determination of Halothane Levels in Hospital Operating Theatres
British Library Conference Proceedings | 2003
|