A platform for research: civil engineering, architecture and urbanism
Evaluation of seismic capacity on the building law Faculty Tadulako University due to Palu earthquake 2018
Indonesia is located in a high level of the earthquake risk area. According to USGS data, from December 2004 to October 2009, more than ten large earthquakes occurred and exceeded 5.0 Scale Richter in magnitude. Recently, the major earthquake occurred on September 28, 2018, in Palu City, Central Sulawesi, with 7.4 on the Scale Richter in magnitude and triggered a lot of building damaged. In this study, the seismic capacity of a 3-story reinforced concrete building, which collapsed due to a large earthquake in the city of Palu, was evaluated. The Standard for Seismic Evaluation of Existing Reinforced Concrete Buildings, 2001 from Japan, was used to evaluate the seismic capacity of reinforced concrete. In this analysis only reviews the column structure elements. However, the brick wall elements are considered to determine net column height. The analysis has been done only for the first floor, where there is the maximum shear force on the structure. Seismic capacity is determined by the relationship between the lateral strength and the ductility index. The obtained results of the seismic capacity analysis showed that the total strength index value of the building was 0.307 for the north to south and 0.455. The seismic capacity of this building is compared with the seismic capacity of a reinforced concrete building that survived due to a large earthquake with 7.6 on the Scale Richter in West Sumatra in September 2009. The obtained results show that the strength index value of this building is smaller than that of a building that could survive the 2009 West Sumatra earthquake.
Evaluation of seismic capacity on the building law Faculty Tadulako University due to Palu earthquake 2018
Indonesia is located in a high level of the earthquake risk area. According to USGS data, from December 2004 to October 2009, more than ten large earthquakes occurred and exceeded 5.0 Scale Richter in magnitude. Recently, the major earthquake occurred on September 28, 2018, in Palu City, Central Sulawesi, with 7.4 on the Scale Richter in magnitude and triggered a lot of building damaged. In this study, the seismic capacity of a 3-story reinforced concrete building, which collapsed due to a large earthquake in the city of Palu, was evaluated. The Standard for Seismic Evaluation of Existing Reinforced Concrete Buildings, 2001 from Japan, was used to evaluate the seismic capacity of reinforced concrete. In this analysis only reviews the column structure elements. However, the brick wall elements are considered to determine net column height. The analysis has been done only for the first floor, where there is the maximum shear force on the structure. Seismic capacity is determined by the relationship between the lateral strength and the ductility index. The obtained results of the seismic capacity analysis showed that the total strength index value of the building was 0.307 for the north to south and 0.455. The seismic capacity of this building is compared with the seismic capacity of a reinforced concrete building that survived due to a large earthquake with 7.6 on the Scale Richter in West Sumatra in September 2009. The obtained results show that the strength index value of this building is smaller than that of a building that could survive the 2009 West Sumatra earthquake.
Evaluation of seismic capacity on the building law Faculty Tadulako University due to Palu earthquake 2018
Medriosa Hamdeni (author)
2020
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Seismic capacity evaluation of the damaged reinforced concrete building during Palu earthquake 2018
DOAJ | 2020
|Building Performance and Geotechnical Failures in 7.5M Palu Earthquake and Tsunami 28 September 2018
Springer Verlag | 2021
|