New Approach for Characterization and Mitigation of the Swelling Phenomenon
This article first introduces a new method of characterization of expansive clays after oedometer test results performed on intact saturated clay specimens. On the presumed expansive clays specimens, oedometer tests are preceded by the free swelling test from which the swelling pressure is measured. From current oedometer test results carried out on expansive and non-expansive clays, the ratio of compression index (Cc) by the swelling index (Cs) was determined. A threshold value of the ratio Cc/Cs was identified to distinguish between expansive clay specimens and non-expansive clay specimens. Second, a novel mitigation method of the swelling phenomena was validated by performing oedometer tests on expansive clay specimens preceding the measurement of swelling pressure. Oedometer tests performed on a 53% thickness clay specimen overlaid by a 47% thickness of sand showed a significant reduction of the swelling pressure compared to that measured on a full expansive clay specimen. The mitigation solution reduced the swelling effect by placing a compacted granular layer as an interface between the expansive clay and the foundation. This solution has been adopted and approved in forthcoming a lightweight building construction at the Faculty of Sciences of Tunis City.
New Approach for Characterization and Mitigation of the Swelling Phenomenon
This article first introduces a new method of characterization of expansive clays after oedometer test results performed on intact saturated clay specimens. On the presumed expansive clays specimens, oedometer tests are preceded by the free swelling test from which the swelling pressure is measured. From current oedometer test results carried out on expansive and non-expansive clays, the ratio of compression index (Cc) by the swelling index (Cs) was determined. A threshold value of the ratio Cc/Cs was identified to distinguish between expansive clay specimens and non-expansive clay specimens. Second, a novel mitigation method of the swelling phenomena was validated by performing oedometer tests on expansive clay specimens preceding the measurement of swelling pressure. Oedometer tests performed on a 53% thickness clay specimen overlaid by a 47% thickness of sand showed a significant reduction of the swelling pressure compared to that measured on a full expansive clay specimen. The mitigation solution reduced the swelling effect by placing a compacted granular layer as an interface between the expansive clay and the foundation. This solution has been adopted and approved in forthcoming a lightweight building construction at the Faculty of Sciences of Tunis City.
New Approach for Characterization and Mitigation of the Swelling Phenomenon
Mounir Bouassida (author) / Sergio Andrew Manigniavy (author) / Dalel Azaiez (author) / Yosra Bouassida (author)
2022
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Theoretical and numerical modeling of swelling phenomenon of rocks in rock excavations
British Library Conference Proceedings
|Study of "swelling" phenomenon during passing of ceramic pastes through a die
British Library Online Contents | 1995
|Using Traditional and Advanced Soil Improvement Techniques for Swelling Soil Heave Mitigation
Springer Verlag | 2020
|