A platform for research: civil engineering, architecture and urbanism
Nonlinear behaviour of liquefied natural gas tanks with different seismic isolation systems
This study determines the effects of different types of base isolator systems on the seismic performance of liquefied natural gas (LNG) storage tanks. Nonlinear time-history analyses of the non-isolated and three different isolated models were performed for the average acceleration of seven ground motions scaled to achieve a specified safe shutdown earthquake. The ANSYS Workbench program was used in the modelling studies of the LNG liquid, inner steel tank, outer shell, ring beam, roof and concrete foundation and side wall insulation. The LS-DYNA program was used for the nonlinear analyses of the LNG liquid, inner steel tank and concrete foundation. The results of the total base shear force, sloshing height, steel tank stresses and lateral deflection were compared. The results indicated that there was no difference between the convective and impulsive modes for the LNG tanks with isolators. It was concluded that the wave motion of the liquid was different from the oscillation of the structure and the earthquake isolation times did not affect the sloshing motion. In the non-isolated system, the stress reached 400 MPa, whereas it was 350 MPa on average in the LNG tanks with isolators.
Nonlinear behaviour of liquefied natural gas tanks with different seismic isolation systems
This study determines the effects of different types of base isolator systems on the seismic performance of liquefied natural gas (LNG) storage tanks. Nonlinear time-history analyses of the non-isolated and three different isolated models were performed for the average acceleration of seven ground motions scaled to achieve a specified safe shutdown earthquake. The ANSYS Workbench program was used in the modelling studies of the LNG liquid, inner steel tank, outer shell, ring beam, roof and concrete foundation and side wall insulation. The LS-DYNA program was used for the nonlinear analyses of the LNG liquid, inner steel tank and concrete foundation. The results of the total base shear force, sloshing height, steel tank stresses and lateral deflection were compared. The results indicated that there was no difference between the convective and impulsive modes for the LNG tanks with isolators. It was concluded that the wave motion of the liquid was different from the oscillation of the structure and the earthquake isolation times did not affect the sloshing motion. In the non-isolated system, the stress reached 400 MPa, whereas it was 350 MPa on average in the LNG tanks with isolators.
Nonlinear behaviour of liquefied natural gas tanks with different seismic isolation systems
İbrahim Hüner (author) / Bülent Akbaş (author) / Abdullah Cem Koç (author)
2023
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Seismic Isolation of Industrial Tanks
British Library Conference Proceedings | 1996
|Seismic vulnerability mitigation of liquefied gas tanks using concave sliding bearings
British Library Online Contents | 2016
|Application of Seismic Isolation to Industrial Tanks
British Library Conference Proceedings | 1995
|