Comparative full-scale fire performance testing of ETICS systems
A full-scale test has been performed to determine fire performance of different ETICS systems (combustible insulation, combustible insulation with fire barrier, non-combustible insulation). Test specimens were constructed and tested according to BS 8414-1:2002, while additional measurements were also conducted to obtain valuable information for better understanding of fire performance of systems used.
Comparative full-scale fire performance testing of ETICS systems
A full-scale test has been performed to determine fire performance of different ETICS systems (combustible insulation, combustible insulation with fire barrier, non-combustible insulation). Test specimens were constructed and tested according to BS 8414-1:2002, while additional measurements were also conducted to obtain valuable information for better understanding of fire performance of systems used.
Comparative full-scale fire performance testing of ETICS systems
Dubravka Bjegović (author) / Ivana Banjad Pečur (author) / Bojan Milovanović (author) / Marija Jelčić Rukavina (author) / Marina Bagarić (author)