A platform for research: civil engineering, architecture and urbanism
Air Leakage of Joints Filled with Polyurethane Foam
Air leakage through the building envelope joints is usually one of the main reasons why airtightness targets are not achieved. The objective of this study was to analyse the air leakage of joints filled with polyurethane foam and its influencing factors. Wooden test specimens (54 in total) with planed, sawn and plastic-coated cavities and two cavity thicknesses were filled with three different polyurethane foams and tested according to standard EN 12114. The surface type and thickness of the joint had a significant effect on the air leakage of joints filled with polyurethane foam. In laboratory conditions, a consistent and very low air leakage rate was obtained with planed timber surfaces. Joints with plastic-coated and sawn timber surfaces performed worse, on average, by a factor of two or more and contributed to very variable airtightness, with up to 28% and 50% of the test specimens failing the airtightness testing. On the basis of the high ‘failure rate’, polyurethane foam may classify as a not completely trustworthy solution in guaranteeing the airtightness of construction joints. A comparison of estimated and previously measured overall airtightness of an entire building envelope showed dependency on ‘failure rate’ rather than on average measured leakage rate.
Air Leakage of Joints Filled with Polyurethane Foam
Air leakage through the building envelope joints is usually one of the main reasons why airtightness targets are not achieved. The objective of this study was to analyse the air leakage of joints filled with polyurethane foam and its influencing factors. Wooden test specimens (54 in total) with planed, sawn and plastic-coated cavities and two cavity thicknesses were filled with three different polyurethane foams and tested according to standard EN 12114. The surface type and thickness of the joint had a significant effect on the air leakage of joints filled with polyurethane foam. In laboratory conditions, a consistent and very low air leakage rate was obtained with planed timber surfaces. Joints with plastic-coated and sawn timber surfaces performed worse, on average, by a factor of two or more and contributed to very variable airtightness, with up to 28% and 50% of the test specimens failing the airtightness testing. On the basis of the high ‘failure rate’, polyurethane foam may classify as a not completely trustworthy solution in guaranteeing the airtightness of construction joints. A comparison of estimated and previously measured overall airtightness of an entire building envelope showed dependency on ‘failure rate’ rather than on average measured leakage rate.
Air Leakage of Joints Filled with Polyurethane Foam
Jaanus Hallik (author) / Heleen Gustavson (author) / Targo Kalamees (author)
2019
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
European Patent Office | 2023
|Filled Polyurethane Foam with Improved Quality Indicators
Springer Verlag | 2023
|PRE PAINTED ALUMINUM PROFILES FILLED WITH POLYURETHANE FOAM
European Patent Office | 2022
|Polyurethane Foam-Filled Energy Absorption Connectors Under Impact
Springer Verlag | 2022
|