A platform for research: civil engineering, architecture and urbanism
Innovative Seismic Response-Controlled System with Shear Wall and Concentrated Dampers in Lower Stories
A new structural control system using damper-installed shear walls in lower stories with reduced stiffness is proposed for vibration control of high-rise RC buildings. That system has some design variables, i.e., height of shear wall, degree of stiffness reduction at lower stories, and quantity of dampers. In this paper, some parametric studies on the shear-beam model with a stiff beam against two kinds of ground motion, a pulse-type sinusoidal wave and a resonant sinusoidal wave, are conducted to clarify the vibration characteristics of the proposed structural control system. It is shown that the optimal combination of design parameters depends on the input ground motion. It is also shown that it is possible to prevent from increasing the response under the one-cycle sinusoidal input resonant to the lowest mode and reduce the steady-state response under the harmonic input with the resonant fundamental period by reducing the stiffness in the lower structure and increasing the damper deformation.
Innovative Seismic Response-Controlled System with Shear Wall and Concentrated Dampers in Lower Stories
A new structural control system using damper-installed shear walls in lower stories with reduced stiffness is proposed for vibration control of high-rise RC buildings. That system has some design variables, i.e., height of shear wall, degree of stiffness reduction at lower stories, and quantity of dampers. In this paper, some parametric studies on the shear-beam model with a stiff beam against two kinds of ground motion, a pulse-type sinusoidal wave and a resonant sinusoidal wave, are conducted to clarify the vibration characteristics of the proposed structural control system. It is shown that the optimal combination of design parameters depends on the input ground motion. It is also shown that it is possible to prevent from increasing the response under the one-cycle sinusoidal input resonant to the lowest mode and reduce the steady-state response under the harmonic input with the resonant fundamental period by reducing the stiffness in the lower structure and increasing the damper deformation.
Innovative Seismic Response-Controlled System with Shear Wall and Concentrated Dampers in Lower Stories
Tsubasa Tani (author) / Ryota Maseki (author) / Izuru Takewaki (author)
2017
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Mitigating seismic response of shear wall structures using embedded dampers
British Library Online Contents | 2006
|Ultra High-rise Building with High Seismic Performance and Dampers Concentrated on Specific Stories
British Library Conference Proceedings | 2015
|Seismic Response Study on Masonry Buildings with Lower Stories of R. C. Frame-Shear Wall Structure
British Library Conference Proceedings | 1997
|Seismic response of controlled structures with active multiple tuned mass dampers
Online Contents | 2006
|