Hybrid Control Strategy for Air-conditioning Loads Participating in Peak Load Reduction Through Wide-range Transport Model
This paper proposes a hybrid control strategy of air-conditioning loads (ACLs) for participating in peak load reduction. The hybrid control strategy combines the temperature setpoint adjustment (TSA) control and on/off control together to make full use of response potentials of ACLs. The primary free transport model of ACLs has been established in literature at or near a fixed temperature setpoint. In this paper, a wide-range transport (WRT) model suitable for larger value of TSA is proposed. The WRT model can be constructed easily through the parameter of devices and indoor and outdoor temperature. To modulate the aggregate response characteristics of ACLs more friendly to the power grid, the safe protocol (SP) is adopted and integrated into the WRT model, which achieves a good unification of oscillation suppression and efficient modeling. Moreover, the hybrid control strategy is implemented based on the WRT model, and the model predictive control (MPC) controller is designed considering the tracking error and control switch cost. At last, the superiority of the hybrid control strategy is verified and the performance of ACLs for peak load reduction under this controller is simulated. The simulation results show that the hybrid control strategy could exploit the load reduction potential of ACLs fully than the TSA mode and track the reference signal more accurately.
Hybrid Control Strategy for Air-conditioning Loads Participating in Peak Load Reduction Through Wide-range Transport Model
This paper proposes a hybrid control strategy of air-conditioning loads (ACLs) for participating in peak load reduction. The hybrid control strategy combines the temperature setpoint adjustment (TSA) control and on/off control together to make full use of response potentials of ACLs. The primary free transport model of ACLs has been established in literature at or near a fixed temperature setpoint. In this paper, a wide-range transport (WRT) model suitable for larger value of TSA is proposed. The WRT model can be constructed easily through the parameter of devices and indoor and outdoor temperature. To modulate the aggregate response characteristics of ACLs more friendly to the power grid, the safe protocol (SP) is adopted and integrated into the WRT model, which achieves a good unification of oscillation suppression and efficient modeling. Moreover, the hybrid control strategy is implemented based on the WRT model, and the model predictive control (MPC) controller is designed considering the tracking error and control switch cost. At last, the superiority of the hybrid control strategy is verified and the performance of ACLs for peak load reduction under this controller is simulated. The simulation results show that the hybrid control strategy could exploit the load reduction potential of ACLs fully than the TSA mode and track the reference signal more accurately.
Hybrid Control Strategy for Air-conditioning Loads Participating in Peak Load Reduction Through Wide-range Transport Model
Yunfeng Ma (author) / Zengqiang Mi (author) / Ruifeng Zhang (author) / Huowen Peng (author) / Yulong Jia (author)
2022
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Laboratory Testing of Control Strategies to Reduce Peak Air-Conditioning Loads
British Library Online Contents | 1993
|Control strategy for battery-supported photovoltaic systems aimed at peak load reduction
BASE | 2019
|Demand response: a strategy to address residential air-conditioning peak load in Australia
DOAJ | 2013
|Air-conditioning loads that improve load factor
Engineering Index Backfile | 1937
|