A platform for research: civil engineering, architecture and urbanism
Field Investigation of Joints in Precast Post-Tensioned Segmental Concrete Bridges
The precast segmental construction is widely used in the bridge structures erected by balanced-cantilever method. The joints are obviously of the utmost importance in connecting the precast segments of bridge girders. As well as the girders, the joints between segments should be capable of transferring compression, shear, and torsion forces. The basic requirements for match-cast joints are summarised. The joints between segments in many precast concrete bridges constructed by balanced cantilever method were inspected during construction and in service. The results of field survey that are presented in this paper included 5 major bridges. The spans are all precast box girders of constant or varying cross-section. Studies were conducted to determine the geometry and mechanical properties of grouted and match-cast joints. Classification of joint defects is presented. Statistics are given on the defects observed in some boxgirder segmental joints. Photographs of typical joint problems are included.
Field Investigation of Joints in Precast Post-Tensioned Segmental Concrete Bridges
The precast segmental construction is widely used in the bridge structures erected by balanced-cantilever method. The joints are obviously of the utmost importance in connecting the precast segments of bridge girders. As well as the girders, the joints between segments should be capable of transferring compression, shear, and torsion forces. The basic requirements for match-cast joints are summarised. The joints between segments in many precast concrete bridges constructed by balanced cantilever method were inspected during construction and in service. The results of field survey that are presented in this paper included 5 major bridges. The spans are all precast box girders of constant or varying cross-section. Studies were conducted to determine the geometry and mechanical properties of grouted and match-cast joints. Classification of joint defects is presented. Statistics are given on the defects observed in some boxgirder segmental joints. Photographs of typical joint problems are included.
Field Investigation of Joints in Precast Post-Tensioned Segmental Concrete Bridges
Zenonas Kamaitis (author)
2008
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Field Investigation of Joints in Precast Post-Tensioned Segmental Concrete Bridges
BASE | 2008
|Precast Post-tensioned Segmental Box-Girder Bridges in Vancouver, B.C.
British Library Conference Proceedings | 1990
|A Precast Post-Tensioned Segmental Pole System
ASCE | 2002
|METHODS FOR SPLICED PRETENSIONED/POST-TENSIONED PRECAST CONCRETE BRIDGES
British Library Conference Proceedings | 2000
|