A platform for research: civil engineering, architecture and urbanism
A global asymptotical stable control scheme for a Hexverter in fractional frequency transmission systems
A fractional frequency transmission system (FFTS) is the most competitive choice for long distance transmission of offshore wind power, while the Hexverter, as a newly proposed direct AC/AC converter, is an attractive choice for its power conversion. This paper proposes a novel control scheme characterizing the global stability and strong robustness of the Hexverter in FFTS applications, which are based on the interconnection and damping assignment passivity-based control (IDA-PBC) methodology. Firstly, the frequency decoupled model of the Hexverter is studied and then a port-controlled Hamiltonian (PCH) model is built. On this basis, the IDA-PB control scheme of the Hexverter is designed. Considering the interference of system parameters and unmodeled dynamics, integrators are added to the IDA-PB controller to eliminate the steady-state error. In addition, the voltage-balancing control is applied in order to balance the capacitor DC voltages to obtain a better performance. Finally, the simulation results and experimental results are presented to verify the effectiveness and superiority of the IDA-PB controller.
A global asymptotical stable control scheme for a Hexverter in fractional frequency transmission systems
A fractional frequency transmission system (FFTS) is the most competitive choice for long distance transmission of offshore wind power, while the Hexverter, as a newly proposed direct AC/AC converter, is an attractive choice for its power conversion. This paper proposes a novel control scheme characterizing the global stability and strong robustness of the Hexverter in FFTS applications, which are based on the interconnection and damping assignment passivity-based control (IDA-PBC) methodology. Firstly, the frequency decoupled model of the Hexverter is studied and then a port-controlled Hamiltonian (PCH) model is built. On this basis, the IDA-PB control scheme of the Hexverter is designed. Considering the interference of system parameters and unmodeled dynamics, integrators are added to the IDA-PB controller to eliminate the steady-state error. In addition, the voltage-balancing control is applied in order to balance the capacitor DC voltages to obtain a better performance. Finally, the simulation results and experimental results are presented to verify the effectiveness and superiority of the IDA-PB controller.
A global asymptotical stable control scheme for a Hexverter in fractional frequency transmission systems
Yongqing Meng (author) / Yichao Zou (author) / Huixuan Li (author) / Jianyang Yu (author) / Xifan Wang (author)
2019
Article (Journal)
Electronic Resource
Unknown
Fractional frequency transmission system (FFTS) , Hexverter , Port-controlled Hamiltonian (PCH) system , Interconnection and damping assignment passivity-based control (IDA-PBC) , Production of electric energy or power. Powerplants. Central stations , TK1001-1841 , Renewable energy sources , TJ807-830
Metadata by DOAJ is licensed under CC BY-SA 1.0
Inserted perturbations generating asymptotical integrability
British Library Online Contents | 2014
|An Asymptotical Stability in Variational Sense for Second Order Systems
British Library Online Contents | 2010
|British Library Online Contents | 2008
|British Library Online Contents | 2014
|