PERBANDINGAN DAYA DUKUNG TIANG PANCANG BERDASARKAN PENGUJIAN CONE PENETRATION TEST (CPT) DAN STANDARD PENETRATION TEST (SPT) PADA TANAH BERPASIR
Design of building structure always related to the foundation, field testing is often done to test the bearing capacity of the soil in the form of a cone penetration test (CPT) and a standard penetration test (SPT). From the two field tests that are often done, it is necessary to research the amount of bearing capacity obtained through CPT and SPT data. This study uses a bearing capacity analysis of the pile foundation using CPT and SPT data in Pesanggaran, Bali, Indonesia. The analysis was carried out by comparing the bearing capacity of pile foundations using pile foundations with dimensions of 15 cm, 20 cm, 25 cm and 30 cm at a level of 10 meters. The results of the bearing capacity percentage are then compared. From the analysis conducted, the bearing capacity of pile foundations using CPT data has a higher value than the carrying capacity of poles using SPT data with a bearing capacity difference of 10,4-16,3%.
PERBANDINGAN DAYA DUKUNG TIANG PANCANG BERDASARKAN PENGUJIAN CONE PENETRATION TEST (CPT) DAN STANDARD PENETRATION TEST (SPT) PADA TANAH BERPASIR
Design of building structure always related to the foundation, field testing is often done to test the bearing capacity of the soil in the form of a cone penetration test (CPT) and a standard penetration test (SPT). From the two field tests that are often done, it is necessary to research the amount of bearing capacity obtained through CPT and SPT data. This study uses a bearing capacity analysis of the pile foundation using CPT and SPT data in Pesanggaran, Bali, Indonesia. The analysis was carried out by comparing the bearing capacity of pile foundations using pile foundations with dimensions of 15 cm, 20 cm, 25 cm and 30 cm at a level of 10 meters. The results of the bearing capacity percentage are then compared. From the analysis conducted, the bearing capacity of pile foundations using CPT data has a higher value than the carrying capacity of poles using SPT data with a bearing capacity difference of 10,4-16,3%.
PERBANDINGAN DAYA DUKUNG TIANG PANCANG BERDASARKAN PENGUJIAN CONE PENETRATION TEST (CPT) DAN STANDARD PENETRATION TEST (SPT) PADA TANAH BERPASIR
I Wayan Ariyana Basoka (author)
2020
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Analisis Daya Dukung Tiang Bor Berdasarkan Standard Penetration Test (Spt) Dan Hasil Reaction Pile