A platform for research: civil engineering, architecture and urbanism
Determination of Mechanical Properties of Soils Based on CPTU Data
The study aimed to interpret the results of cone penetration tests with pore pressure measurement (CPTU). Tests were performed on a section of the designed road about 200 m long. The subsoil under consideration was characterized by organic soils deposited to a depth of approximately 8 m. Due to the problematic soil and water conditions, improvement with geosynthetic encased columns (GEC) was performed. According to the Recommendations for Design and Analysis of Earth Structures using Geosynthetic Reinforcements – EBGEO, the constrained modulus Eoed and effective friction angle φ’ of soil below the GEC column base should be higher than 5 MPa (Eoed > 5 MPa) and 30° (φ’ > 30°), respectively. In this study, the Eoed and φ’ parameters were determined based on CPTU tests conducted in 12 locations. Analysis of the CPTU data showed that the constrained modulus and effective friction angle of the soil deposited below the GEC column base did not meet EBGEO requirements in most locations. It was also concluded that the minimum value of the constrained modulus required by EBGEO is too low compared with the requested value of the effective friction angle.
Determination of Mechanical Properties of Soils Based on CPTU Data
The study aimed to interpret the results of cone penetration tests with pore pressure measurement (CPTU). Tests were performed on a section of the designed road about 200 m long. The subsoil under consideration was characterized by organic soils deposited to a depth of approximately 8 m. Due to the problematic soil and water conditions, improvement with geosynthetic encased columns (GEC) was performed. According to the Recommendations for Design and Analysis of Earth Structures using Geosynthetic Reinforcements – EBGEO, the constrained modulus Eoed and effective friction angle φ’ of soil below the GEC column base should be higher than 5 MPa (Eoed > 5 MPa) and 30° (φ’ > 30°), respectively. In this study, the Eoed and φ’ parameters were determined based on CPTU tests conducted in 12 locations. Analysis of the CPTU data showed that the constrained modulus and effective friction angle of the soil deposited below the GEC column base did not meet EBGEO requirements in most locations. It was also concluded that the minimum value of the constrained modulus required by EBGEO is too low compared with the requested value of the effective friction angle.
Determination of Mechanical Properties of Soils Based on CPTU Data
Chmielewska Iwona (author)
2023
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Geotechnical properties of silty alluvial soils from CPTU tests
British Library Conference Proceedings | 2001
|British Library Conference Proceedings | 1998
|Liquefaction Assessment of Gulf of Kutch Offshore Soils Using CPTU Data
Springer Verlag | 2021
|Evaluation of Field CPTU Dissipation Data in Overconsolidated Fine-Grained Soils
British Library Conference Proceedings | 1994
|