A platform for research: civil engineering, architecture and urbanism
Investigation on Electrically Conductive Aggregates as Grounding Compound Produced by Marconite
Marconite is often used as alternative material to improve the performance of earth grounding system. This study aims to investigate of the physical and mechanical behaviour of conductive aggregate derived from Marconite namely, the electrical resistivity, water absorption, and crushing strength. In addition, similar tests were also conducted on mortar aggregate for comparison. The resistivity of aggregates were measured using soil box method. Test results showed that the electrical resistivity, water absorption, and crushing strength of both aggregates varied with time. These values were found to be stabilised after approximately after 14 days. The electrical resistivity for aggregates containing Marconite were found to be 39.2 Ω.m, far lower than 12700 Ω.m obtained for mortar-based aggregates. Similarly, the water absorption for Marconite aggregates were greater compared to mortar aggregates. On the other hand, the crushing strength for Marconite aggregates was to be lower. Incorporating Marconite significantly improved the electrical resistivity behaviour while maintaining acceptable mechanical properties crucial for electrical grounding purposes.
Investigation on Electrically Conductive Aggregates as Grounding Compound Produced by Marconite
Marconite is often used as alternative material to improve the performance of earth grounding system. This study aims to investigate of the physical and mechanical behaviour of conductive aggregate derived from Marconite namely, the electrical resistivity, water absorption, and crushing strength. In addition, similar tests were also conducted on mortar aggregate for comparison. The resistivity of aggregates were measured using soil box method. Test results showed that the electrical resistivity, water absorption, and crushing strength of both aggregates varied with time. These values were found to be stabilised after approximately after 14 days. The electrical resistivity for aggregates containing Marconite were found to be 39.2 Ω.m, far lower than 12700 Ω.m obtained for mortar-based aggregates. Similarly, the water absorption for Marconite aggregates were greater compared to mortar aggregates. On the other hand, the crushing strength for Marconite aggregates was to be lower. Incorporating Marconite significantly improved the electrical resistivity behaviour while maintaining acceptable mechanical properties crucial for electrical grounding purposes.
Investigation on Electrically Conductive Aggregates as Grounding Compound Produced by Marconite
Mohd Tadza Mohd Yuhyi (author) / Tengku Anuar Tengku Hafidatul Husna (author) / Mat Yahaya Fadzil (author)
2019
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
British Library Online Contents | 2017
|Electrically conductive concrete grounding electrode material
Tema Archive | 1997
HYDROGEN-CONTAINING ELECTRICALLY CONDUCTIVE INORGANIC COMPOUND
European Patent Office | 2017
|