A platform for research: civil engineering, architecture and urbanism
Evaluation of Seismic Performance of Masonry Stone Pagoda: Dynamic Centrifuge Test and Numerical Simulation Analysis
This study provides a comparison of results from dynamic centrifuge tests and a finite element analysis model to confirm the behavior of a representative Korean stone pagoda cultural heritage structure against earthquakes. The indirect stiffness or physical state of the structure was estimated by measuring the natural frequency of the masonry stone pagoda. The actual natural frequency of the stone pagoda was measured to be 4.5 Hz. It was determined to have a lower natural frequency than other stone pagodas of similar size. For the experiment, a dynamic centrifugal separator test was performed on a 1/15 model. Data from an actual earthquake record, the Ofunato earthquake, were used, with various maximum acceleration levels ranging from 0.069 g to 0.424 g. In order to confirm the accuracy of the finite element analysis model, the measured natural frequency of the masonry stone pagoda was compared with the modal analysis of the finite element model. When the data obtained from the experiment and the PGA (peak ground acceleration) of the FEM analysis with a complex masonry stone pagoda using a validated model result were compared, it was found to have a low average error rate of 13%. This shows that structural behavior can be predicted for similar masonry stone pagoda structures using finite element method analysis in the future.
Evaluation of Seismic Performance of Masonry Stone Pagoda: Dynamic Centrifuge Test and Numerical Simulation Analysis
This study provides a comparison of results from dynamic centrifuge tests and a finite element analysis model to confirm the behavior of a representative Korean stone pagoda cultural heritage structure against earthquakes. The indirect stiffness or physical state of the structure was estimated by measuring the natural frequency of the masonry stone pagoda. The actual natural frequency of the stone pagoda was measured to be 4.5 Hz. It was determined to have a lower natural frequency than other stone pagodas of similar size. For the experiment, a dynamic centrifugal separator test was performed on a 1/15 model. Data from an actual earthquake record, the Ofunato earthquake, were used, with various maximum acceleration levels ranging from 0.069 g to 0.424 g. In order to confirm the accuracy of the finite element analysis model, the measured natural frequency of the masonry stone pagoda was compared with the modal analysis of the finite element model. When the data obtained from the experiment and the PGA (peak ground acceleration) of the FEM analysis with a complex masonry stone pagoda using a validated model result were compared, it was found to have a low average error rate of 13%. This shows that structural behavior can be predicted for similar masonry stone pagoda structures using finite element method analysis in the future.
Evaluation of Seismic Performance of Masonry Stone Pagoda: Dynamic Centrifuge Test and Numerical Simulation Analysis
Gayoon Lee (author) / Heon-Joon Park (author) / Khoa V. A. Pham (author) / Jae-Young Kim (author) / Sung-Min Lee (author) / Kihak Lee (author)
2023
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Taylor & Francis Verlag | 2021
|Shaking Table Test on Unreinforced Stone Masonry Pagoda
British Library Conference Proceedings | 2012
|Shaking Table Test on Unreinforced Stone Masonry Pagoda
Tema Archive | 2012
|Shaking Table Test on Unreinforced Stone Masonry Pagoda
Trans Tech Publications | 2012
|Dynamic performance and seismic damage analysis of an ancient masonry pagoda
Taylor & Francis Verlag | 2022
|