Numerical analysis and capacity evaluation of composite sprayed concrete lined tunnels
Spray-applied membranes for waterproofing of sprayed concrete tunnels have led to the possibility of shear transfer between primary and secondary linings through the membrane interface, with the potential for reducing overall lining thickness. Laboratory tests have shown a reasonable degree of composite action in beam specimens. In this study, a numerical model previously calibrated against such tests is applied to a whole tunnel, considering soil–structure interaction and staged lining construction. The model shows composite action, and load sharing between the lining layers is expected in the tunnel as in the beams. Parametric studies over the practical range of interface stiffness values show that composite action is maintained, although at high interface stiffness, excessive bending may be imposed on the secondary lining, requiring additional reinforcement. An efficient composite shell design with minimal additional reinforcement is achievable if the secondary lining thickness is reduced as compared to current practice. Robustness of the system, measured in terms of the interface’s ability to transfer stress under unequal loading causing distortion on the tunnel, is found to be generally adequate. However, adjacent construction in close proximity may provide insufficient margin on membrane tensile de-bonding, particularly if the membrane is partially or fully saturated. Keywords: Composite sprayed concrete lining, Spray-applied waterproofing membrane, Interface parameters, Lining efficiency
Numerical analysis and capacity evaluation of composite sprayed concrete lined tunnels
Spray-applied membranes for waterproofing of sprayed concrete tunnels have led to the possibility of shear transfer between primary and secondary linings through the membrane interface, with the potential for reducing overall lining thickness. Laboratory tests have shown a reasonable degree of composite action in beam specimens. In this study, a numerical model previously calibrated against such tests is applied to a whole tunnel, considering soil–structure interaction and staged lining construction. The model shows composite action, and load sharing between the lining layers is expected in the tunnel as in the beams. Parametric studies over the practical range of interface stiffness values show that composite action is maintained, although at high interface stiffness, excessive bending may be imposed on the secondary lining, requiring additional reinforcement. An efficient composite shell design with minimal additional reinforcement is achievable if the secondary lining thickness is reduced as compared to current practice. Robustness of the system, measured in terms of the interface’s ability to transfer stress under unequal loading causing distortion on the tunnel, is found to be generally adequate. However, adjacent construction in close proximity may provide insufficient margin on membrane tensile de-bonding, particularly if the membrane is partially or fully saturated. Keywords: Composite sprayed concrete lining, Spray-applied waterproofing membrane, Interface parameters, Lining efficiency
Numerical analysis and capacity evaluation of composite sprayed concrete lined tunnels
Alan Bloodworth (author) / Jiang Su (author)
2018
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Sprayed concrete lined tunnels
TIBKAT | 2020
|Sprayed concrete lined tunnels : an introduction
TIBKAT | 2009
|Book review: Sprayed Concrete Lined Tunnels
Online Contents | 2010
|3D modelling of sprayed-concrete-lined tunnels in clay
British Library Online Contents | 2006
|3D modelling of sprayed concrete lined tunnels in clay
British Library Online Contents | 2007
|