Long-Term Neutralization of Acidic Condensate from Gas Condensing Boilers
The pH of wastewater needs to remain between 6 and 9 to protect water organisms. Condensates from a gas condensing boiler have a pH value of about 3. An optimal way to neutralize the acid condensate is to use cheap material such as dolomite. An old-style neutralization box (NB) was tested with a standard faction of dolomite. However, it did not sufficiently neutralize the condensate. Therefore, several tests were performed involving changes to the construction of the neutralization box, a finer fraction of dolomite and aerating the condensate in the neutralization box. In summary, a new NB technology with partitions, a finer fraction of dolomite and condensate aeration proved sufficient in the neutralization of the pH of the condensate in the short and long terms. It depends on what material the heat exchanger is made of in the condensing boiler. The aluminum content reduces the effectiveness of dolomite in the long run, so aerating the condensate in the NB is recommended, which leads to its more effective neutralization.
Long-Term Neutralization of Acidic Condensate from Gas Condensing Boilers
The pH of wastewater needs to remain between 6 and 9 to protect water organisms. Condensates from a gas condensing boiler have a pH value of about 3. An optimal way to neutralize the acid condensate is to use cheap material such as dolomite. An old-style neutralization box (NB) was tested with a standard faction of dolomite. However, it did not sufficiently neutralize the condensate. Therefore, several tests were performed involving changes to the construction of the neutralization box, a finer fraction of dolomite and aerating the condensate in the neutralization box. In summary, a new NB technology with partitions, a finer fraction of dolomite and condensate aeration proved sufficient in the neutralization of the pH of the condensate in the short and long terms. It depends on what material the heat exchanger is made of in the condensing boiler. The aluminum content reduces the effectiveness of dolomite in the long run, so aerating the condensate in the NB is recommended, which leads to its more effective neutralization.
Long-Term Neutralization of Acidic Condensate from Gas Condensing Boilers
Jiří Horák (author) / Lenka Kuboňová (author) / Milan Dej (author) / Jiří Ryšavý (author) / Stanislav Bajer (author) / Zdeněk Kysučan (author) / Pavel Ulrich (author) / Pavel Mareček (author) / Filip Tesař (author) / Martin Garba (author)
2022
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Long term performance evaluation of condensing boilers for building heating
British Library Conference Proceedings | 1998
|Condensing Boilers and Baseboard Hydronic Heating Systems
British Library Online Contents | 2006
|Condensing boilers in buildings and plants refurbishment
Online Contents | 2012
|Condensing boilers in buildings and plants refurbishment
Elsevier | 2011
|