A platform for research: civil engineering, architecture and urbanism
Rationalization of the constructive form of towers with prestressed cables
Relevance. One of the main directions of development of mobile communication systems, radio engineering and telecommunication systems is the improvement of the structural form of the bearing supports, which will solve a number of practical tasks: to increase the coverage area, to ensure higher rates of data transmission speed and to ensure stable operation in an increasing number of users. These circumstances justify the relevance of research in this direction. Aims of research. Optimization of design solutions using parallel puffs, ensuring the possibility of erection and safe operation during the entire service life, which ensures that the requirements for strength, stability and deformations for such structures are met with minimal material consumption. Methods. For calculations, finite element methods are used for mathematical modeling using software and computing systems. To create linear models for numerical experiments, the method of mathematical planning of experiments was used. Results. The work of the towers of the proposed constructive solution is considered as supports for the placement of equipment of cellular operators using the example of a 42-meter tower. The method of mathematical planning of experiments was used to create a model line for numerical experiments. To establish the basic characteristics of the stress-strain state of the structures of the supports, a number of models were created and calculated in software packages, the basis of which is the finite element method. A comparative analysis of the effort in the delays determined by analytical calculation and the finite element method is performed. The analysis of changes in the stress-strain state of the towers from the influence of influencing factors, such as wind and icy-wind loads, the angle of deflection on the lower tier of the tower. By the criterion of minimum metal consumption and manufacturability of the construction of towers, rational overall dimensions of the tower were determined. The options for constructing the main junctions of the elements of the tower are proposed.
Rationalization of the constructive form of towers with prestressed cables
Relevance. One of the main directions of development of mobile communication systems, radio engineering and telecommunication systems is the improvement of the structural form of the bearing supports, which will solve a number of practical tasks: to increase the coverage area, to ensure higher rates of data transmission speed and to ensure stable operation in an increasing number of users. These circumstances justify the relevance of research in this direction. Aims of research. Optimization of design solutions using parallel puffs, ensuring the possibility of erection and safe operation during the entire service life, which ensures that the requirements for strength, stability and deformations for such structures are met with minimal material consumption. Methods. For calculations, finite element methods are used for mathematical modeling using software and computing systems. To create linear models for numerical experiments, the method of mathematical planning of experiments was used. Results. The work of the towers of the proposed constructive solution is considered as supports for the placement of equipment of cellular operators using the example of a 42-meter tower. The method of mathematical planning of experiments was used to create a model line for numerical experiments. To establish the basic characteristics of the stress-strain state of the structures of the supports, a number of models were created and calculated in software packages, the basis of which is the finite element method. A comparative analysis of the effort in the delays determined by analytical calculation and the finite element method is performed. The analysis of changes in the stress-strain state of the towers from the influence of influencing factors, such as wind and icy-wind loads, the angle of deflection on the lower tier of the tower. By the criterion of minimum metal consumption and manufacturability of the construction of towers, rational overall dimensions of the tower were determined. The options for constructing the main junctions of the elements of the tower are proposed.
Rationalization of the constructive form of towers with prestressed cables
Ivan R. Sitnikov (author) / Alexander V. Golikov (author)
2019
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Prestressed hyperbolic water towers
Engineering Index Backfile | 1949
|Construction of prestressed concrete towers
Wiley | 2013
|Engineering Index Backfile | 1941
|Structural behaviour of prestressed GRC towers
British Library Conference Proceedings | 2001
|Monoleg Towers with Transverse Stabilising Cables
British Library Online Contents | 1998
|