A platform for research: civil engineering, architecture and urbanism
Evaluation of Soil Shear Strength Parameters Via Triaxial Testing by Height Versus Diameter Ratio of Sample
The triaxial test is a most widely used laboratory method for determining the soil shear strength. It is assumed that a soil sample deforms uniformly during triaxial testing. But one often faces a case when the sample in the triaxial apparatus deforms on the contrary. The non-uniformity can be caused by the end restraining effect, the sample height influence factor, the insufficient drainage, the membrane effect and the sample self-weight factor etc. An analysis of known investigations lead to the following tools that could be employed for reducing an inaccuracy related to the non-uniform stress-strain distribution per soil sample during triaxial testing: reducing the sample height/diameter ratio from 2 to 1, eliminating the friction between the sample ends and the plates. Having not eliminated the above - mentioned influence, factors during the testing procedure the angle of internal friction φ and the cohesion c for the sample of φ ≠ 0 are determined larger than the actual ones. The method for determining the angle of internal friction φ and the cohesion c, when testing the soil sample of height/diameter H/D = 1 is proposed.
Evaluation of Soil Shear Strength Parameters Via Triaxial Testing by Height Versus Diameter Ratio of Sample
The triaxial test is a most widely used laboratory method for determining the soil shear strength. It is assumed that a soil sample deforms uniformly during triaxial testing. But one often faces a case when the sample in the triaxial apparatus deforms on the contrary. The non-uniformity can be caused by the end restraining effect, the sample height influence factor, the insufficient drainage, the membrane effect and the sample self-weight factor etc. An analysis of known investigations lead to the following tools that could be employed for reducing an inaccuracy related to the non-uniform stress-strain distribution per soil sample during triaxial testing: reducing the sample height/diameter ratio from 2 to 1, eliminating the friction between the sample ends and the plates. Having not eliminated the above - mentioned influence, factors during the testing procedure the angle of internal friction φ and the cohesion c for the sample of φ ≠ 0 are determined larger than the actual ones. The method for determining the angle of internal friction φ and the cohesion c, when testing the soil sample of height/diameter H/D = 1 is proposed.
Evaluation of Soil Shear Strength Parameters Via Triaxial Testing by Height Versus Diameter Ratio of Sample
Jonas Amšiejus (author) / Neringa Dirgėlienė (author) / Arnoldas Norkus (author) / Daiva Žilionienė (author)
2009
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Effects of end conditions on soil shear strength parameters during triaxial testing
British Library Conference Proceedings | 2007
|European Patent Office | 2021
|Probabilistic Assessment of Soil Shear Strength Parameters Using Triaxial Test Results
DOAJ | 2007
|Soil parameters determined by triaxial testing
British Library Conference Proceedings | 1995
|Assessment of Effective Shear Strength Parameters in Triaxial CU Shear Test
Springer Verlag | 2022
|