A platform for research: civil engineering, architecture and urbanism
Seismic Performance of Steel Structure-Foundation Systems Designed According to Eurocode 8 Provisions: The Case of Near-Fault Seismic Motions
The seismic performance of steel structure-foundation systems subjected to near-fault earthquakes was assessed on the basis of response results from nonlinear time-history seismic analyses. The structural results included the maximum values for residual interstory drift ratios, base shears, and overturning moments of the steel structures, as well as the maximum values for residual settlement and tilting of the foundations. In order to reveal the influence of soil-building-interaction on the aforementioned response results, the steel building-foundation systems were designed according to Eurocode 8 provisions, assuming initially fixed and then compliant base conditions. It was concluded that for the case of near-fault seismic motions, good seismic performance of steel building-foundation hybrid systems designed according to European Codes was not guaranteed. A particular thing to note for these systems under near-fault seismic motions was that the seismic performance of the steel structure was most likely unacceptable, while one of the foundations was always acceptable.
Seismic Performance of Steel Structure-Foundation Systems Designed According to Eurocode 8 Provisions: The Case of Near-Fault Seismic Motions
The seismic performance of steel structure-foundation systems subjected to near-fault earthquakes was assessed on the basis of response results from nonlinear time-history seismic analyses. The structural results included the maximum values for residual interstory drift ratios, base shears, and overturning moments of the steel structures, as well as the maximum values for residual settlement and tilting of the foundations. In order to reveal the influence of soil-building-interaction on the aforementioned response results, the steel building-foundation systems were designed according to Eurocode 8 provisions, assuming initially fixed and then compliant base conditions. It was concluded that for the case of near-fault seismic motions, good seismic performance of steel building-foundation hybrid systems designed according to European Codes was not guaranteed. A particular thing to note for these systems under near-fault seismic motions was that the seismic performance of the steel structure was most likely unacceptable, while one of the foundations was always acceptable.
Seismic Performance of Steel Structure-Foundation Systems Designed According to Eurocode 8 Provisions: The Case of Near-Fault Seismic Motions
Panagiota Katsimpini (author) / Foteini Konstandakopoulou (author) / George Papagiannopoulos (author) / Nikos Pnevmatikos (author) / George Hatzigeorgiou (author)
2020
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
British Library Conference Proceedings | 2009
|British Library Conference Proceedings | 2003
|Safety of RAC-Beams Designed According to Eurocode 2 Provisions
British Library Conference Proceedings | 1998
|