Finnish Guidelines of Ventilation Rates for Non-residential Buildings
The new Finnish Decree on the Indoor Climate and Ventilation of New Buildings 1009/2017 [1] is part of the implementation of Energy Performance of Buildings Directive in the EU. The new Decree specifies the minimum design ventilation rate to be 6 dm3/s, person (outdoor air). The Decree also specifies that the ventilation shall be controlled by demand when feasible. These requirements in the Decree were considered to be too plain and inadequate for practical design. FINVAC carried out an investigation [2,3] regarding the experience on the old ventilation regulation [4]. Based on the result of these investigations new guidelines were prepared and published in 2018. Majority of the experts considered 6 dm3/s, person as an appropriate value of the minimum ventilation rate. The investigations revealed that in many cases the old recommended values (dm3/s, m2) were either too high or too low. This has led to poor air quality in some cases and excess energy use in some cases. Too high ventilation rates were used for corridors, restaurants, cafeterias, supermarkets, department stores, shops, hotel rooms, auditoriums, halls, and washing rooms. The total air flow was also too high for day care centres, and for some apartments. Too low ventilation rates were given for elderly homes, classrooms, fitness centres, sports halls, residential kitchen hoods, operation rooms in hospitals, and for some apartments. Detailed guidelines were prepared and structured by building type (offices, schools, hospitals, elderly homes, restaurants, hotels, stores, sports facilities, barracks, theatres, industrial working places, kitchens, spaces for personal hygiene and technical rooms). Separate guidelines were prepared for residential buildings [5]. Both guidelines were published in the beginning of the year 2018.
Finnish Guidelines of Ventilation Rates for Non-residential Buildings
The new Finnish Decree on the Indoor Climate and Ventilation of New Buildings 1009/2017 [1] is part of the implementation of Energy Performance of Buildings Directive in the EU. The new Decree specifies the minimum design ventilation rate to be 6 dm3/s, person (outdoor air). The Decree also specifies that the ventilation shall be controlled by demand when feasible. These requirements in the Decree were considered to be too plain and inadequate for practical design. FINVAC carried out an investigation [2,3] regarding the experience on the old ventilation regulation [4]. Based on the result of these investigations new guidelines were prepared and published in 2018. Majority of the experts considered 6 dm3/s, person as an appropriate value of the minimum ventilation rate. The investigations revealed that in many cases the old recommended values (dm3/s, m2) were either too high or too low. This has led to poor air quality in some cases and excess energy use in some cases. Too high ventilation rates were used for corridors, restaurants, cafeterias, supermarkets, department stores, shops, hotel rooms, auditoriums, halls, and washing rooms. The total air flow was also too high for day care centres, and for some apartments. Too low ventilation rates were given for elderly homes, classrooms, fitness centres, sports halls, residential kitchen hoods, operation rooms in hospitals, and for some apartments. Detailed guidelines were prepared and structured by building type (offices, schools, hospitals, elderly homes, restaurants, hotels, stores, sports facilities, barracks, theatres, industrial working places, kitchens, spaces for personal hygiene and technical rooms). Separate guidelines were prepared for residential buildings [5]. Both guidelines were published in the beginning of the year 2018.
Finnish Guidelines of Ventilation Rates for Non-residential Buildings
Seppänen Olli (author) / Säteri Jorma (author) / Ahola Mervi (author)
2019
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Performance of Ventilation in Residential Buildings
NTIS | 1987
|VENTILATION-LIMITED FIRES IN RESIDENTIAL BUILDINGS
British Library Online Contents | 2013
|Ventilation Strategies for Non-Residential Buildings
NTIS | 1987
|Finnish architects' attitudes towards multi-storey timber-residential buildings
Emerald Group Publishing | 2024
|