Performance of the Pressure Assisted Forward Osmosis-MSF Hybrid Desalination Plant
An osmotically driven membrane process was proposed for seawater pretreatment in a multi-stage flashing (MSF) thermal plant. Brine reject from the MSF plant was the draw solution (DS) in the forward osmosis (FO) process in order to reduce chemical use. The purpose of FO is the removal of divalent ions from seawater prior the thermal desalination. In this study, seawater at 80 g/L and 45 g/L concentrations were used as the brine reject and seawater, respectively. The temperature of the brine reject was 40 °C and of seawater was 25 °C. Commercial thin-film composite (TFC) and cellulose triacetate (CTA) membranes were evaluated for the pretreatment of seawater in the FO and the pressure-assisted FO (PAFO) processes. Experimental results showed 50% more permeation flux by increasing the feed pressure from 1 to 4 bar, and permeation flux reached 16.7 L/m2h in the PAFO process with a TFC membrane compared to 8.3 L/m2h in the PAFO process with CTA membrane. TFC membrane experienced up to 15% reduction in permeation flux after cleaning with DI water while permeation flux reduction in the CTA membrane was >6%. The maximum recovery rate was 11.5% and 8.8% in the PAFO process with TFC and CTA membrane, respectively. The maximum power consumption for the pretreatment of seawater was 0.06 kWh/m3 and 0.1 kWh/m3 for the PAFO process with a TFC and CTA membrane, respectively.
Performance of the Pressure Assisted Forward Osmosis-MSF Hybrid Desalination Plant
An osmotically driven membrane process was proposed for seawater pretreatment in a multi-stage flashing (MSF) thermal plant. Brine reject from the MSF plant was the draw solution (DS) in the forward osmosis (FO) process in order to reduce chemical use. The purpose of FO is the removal of divalent ions from seawater prior the thermal desalination. In this study, seawater at 80 g/L and 45 g/L concentrations were used as the brine reject and seawater, respectively. The temperature of the brine reject was 40 °C and of seawater was 25 °C. Commercial thin-film composite (TFC) and cellulose triacetate (CTA) membranes were evaluated for the pretreatment of seawater in the FO and the pressure-assisted FO (PAFO) processes. Experimental results showed 50% more permeation flux by increasing the feed pressure from 1 to 4 bar, and permeation flux reached 16.7 L/m2h in the PAFO process with a TFC membrane compared to 8.3 L/m2h in the PAFO process with CTA membrane. TFC membrane experienced up to 15% reduction in permeation flux after cleaning with DI water while permeation flux reduction in the CTA membrane was >6%. The maximum recovery rate was 11.5% and 8.8% in the PAFO process with TFC and CTA membrane, respectively. The maximum power consumption for the pretreatment of seawater was 0.06 kWh/m3 and 0.1 kWh/m3 for the PAFO process with a TFC and CTA membrane, respectively.
Performance of the Pressure Assisted Forward Osmosis-MSF Hybrid Desalination Plant
Daoud Khanafer (author) / Sudesh Yadav (author) / Namuun Ganbat (author) / Ali Altaee (author) / John Zhou (author) / Alaa H. Hawari (author)
2021
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Desalination: From Reverse to Forward Osmosis
British Library Conference Proceedings | 2013
|Forward osmosis desalination from laboratory to market
Online Contents | 2015
|Seawater desalination and reverse osmosis plant design
Tema Archive | 1980
|Evaluation of polyvinylpyrrolidone as draw solute for desalination forward osmosis systems
DOAJ | 2022
|