Maintenance Optimization of Industrial Chimneys Exposed to Carbonation
The paper is focused on the deterioration of industrial reinforced concrete chimneys caused by carbonation. It is considered that a chimney has to be repaired when more than 30% of its surface is affected by visible corrosion-induced cracks. An optimal maintenance strategy aims at the postponement of this state beyond the intended service life of the chimney with minimum maintenance costs.
Maintenance Optimization of Industrial Chimneys Exposed to Carbonation
The paper is focused on the deterioration of industrial reinforced concrete chimneys caused by carbonation. It is considered that a chimney has to be repaired when more than 30% of its surface is affected by visible corrosion-induced cracks. An optimal maintenance strategy aims at the postponement of this state beyond the intended service life of the chimney with minimum maintenance costs.
Maintenance Optimization of Industrial Chimneys Exposed to Carbonation
Mlčoch Jan (author) / Marková Jana (author) / Sýkora Miroslav (author)
2017
Article (Journal)