Analisis Kinerja Bangunan Gedung Tinggi Dengan Penambahan Dinding Geser (Studi Kasus: Bangunan 8 Lantai)
Shear walls in high-rise buildings serve to increase the resistance of high-rise buildings to lateral loads. This study aims to compare the structural performance of an existing 8 (eight) storey building designed as a special moment resisting frame structure against a building designed as a dual system, which consists of: structural vibration time, base shear force, displacement, and drift. Three configurations for shear walls are designed, as follows: (1) L-shaped located at the corner of one side of the building, totaling 2 (two) units (SW1); (2) L-shaped located at the four corners of the building totaling 4 (four) units (SW2); and 3) I-shaped located along the side of the building totaling 6 (six) units (SW3). Simulations are run using the Etabs by taking into account dead loads, live loads, and earthquake loads. The results show that the addition of shear walls can: (1) reduce the vibration period of the structure up to 62,55% in SW3, (2) increase the base shear force up to 86,34% in SW3, (3) reduce peak displacement up to 84,86% in SW3, and (4) reduce the drift between floors up to 89,58% in SW3. However, the SW2 is considered to be better applied to the building by taking into account the structural performance, effectiveness and efficiency factors.
Analisis Kinerja Bangunan Gedung Tinggi Dengan Penambahan Dinding Geser (Studi Kasus: Bangunan 8 Lantai)
Shear walls in high-rise buildings serve to increase the resistance of high-rise buildings to lateral loads. This study aims to compare the structural performance of an existing 8 (eight) storey building designed as a special moment resisting frame structure against a building designed as a dual system, which consists of: structural vibration time, base shear force, displacement, and drift. Three configurations for shear walls are designed, as follows: (1) L-shaped located at the corner of one side of the building, totaling 2 (two) units (SW1); (2) L-shaped located at the four corners of the building totaling 4 (four) units (SW2); and 3) I-shaped located along the side of the building totaling 6 (six) units (SW3). Simulations are run using the Etabs by taking into account dead loads, live loads, and earthquake loads. The results show that the addition of shear walls can: (1) reduce the vibration period of the structure up to 62,55% in SW3, (2) increase the base shear force up to 86,34% in SW3, (3) reduce peak displacement up to 84,86% in SW3, and (4) reduce the drift between floors up to 89,58% in SW3. However, the SW2 is considered to be better applied to the building by taking into account the structural performance, effectiveness and efficiency factors.
Analisis Kinerja Bangunan Gedung Tinggi Dengan Penambahan Dinding Geser (Studi Kasus: Bangunan 8 Lantai)
M Mirza Abdillah Pratama (author) / Septiana Dyah Sugmana Putri (author) / Edi Santoso (author)
2021
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Analisis Dinding Geser pada Desain Bangunan Gedung Bertingkat yang Tidak Beraturan
DOAJ | 2021
|Studi Kefektifan Dinding Geser pada Bangunan Tingkat Tinggi Dalam Mengurangi Simpangan Struktur
BASE | 2021
|