A platform for research: civil engineering, architecture and urbanism
Practical Head-Outflow Relationship Definition Methodology That Accounts for Varied Water-Supply Methods
Achieving reliable pressure-driven analysis (PDA) results that account for anomalies within water-pipe networks requires a head-outflow relationship (HOR) model that can calculate supply flow rate according to the supply pressure at each node. Many studies have suggested HOR models, but a methodology to define HORs that considers the actual residential environment of users and differing water-supply methods for residential buildings has not yet been proposed. This study considered water-use data from buildings and actual differences in residential environments in a surveyed area (including building heights, topography, and water systems within buildings) and water-supply methods (indirect/direct water supply, existence of a pump within buildings) to develop a methodology and derive a representative HOR for the target area for PDA. Further, a representative HOR was determined for each block by applying the developed methodology for two blocks with similar residential environments but different water-use patterns. It confirmed that the HOR induced through this process could provide high water-supply performance despite a low supply head and needed to reflect the diversity of the water-supply method. The proposed HOR-definition methodology can be easily applied in water-pipe network design and operation processes and ensure objectivity and rationality of HOR selection to yield reliable PDA results.
Practical Head-Outflow Relationship Definition Methodology That Accounts for Varied Water-Supply Methods
Achieving reliable pressure-driven analysis (PDA) results that account for anomalies within water-pipe networks requires a head-outflow relationship (HOR) model that can calculate supply flow rate according to the supply pressure at each node. Many studies have suggested HOR models, but a methodology to define HORs that considers the actual residential environment of users and differing water-supply methods for residential buildings has not yet been proposed. This study considered water-use data from buildings and actual differences in residential environments in a surveyed area (including building heights, topography, and water systems within buildings) and water-supply methods (indirect/direct water supply, existence of a pump within buildings) to develop a methodology and derive a representative HOR for the target area for PDA. Further, a representative HOR was determined for each block by applying the developed methodology for two blocks with similar residential environments but different water-use patterns. It confirmed that the HOR induced through this process could provide high water-supply performance despite a low supply head and needed to reflect the diversity of the water-supply method. The proposed HOR-definition methodology can be easily applied in water-pipe network design and operation processes and ensure objectivity and rationality of HOR selection to yield reliable PDA results.
Practical Head-Outflow Relationship Definition Methodology That Accounts for Varied Water-Supply Methods
Dong Eil Chang (author) / Do Guen Yoo (author) / Joong Hoon Kim (author)
2020
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
MANUSCRIPTS - A Damage Model for Practical Seismic Design That Accounts for Low Cycle Fatigue
Online Contents | 2005
|A Newton–Raphson analysis of urban water systems based on nodal head-driven outflow
Taylor & Francis Verlag | 2014
|