Experimental Analysis of the Thermal Performance of a Sunspace Attached to a House with a Central Air Conditioning System
In this paper, the thermal performance of a sunspace attached to a house with a central air conditioning system was experimentally investigated. The house with a south-facing sunspace is located in Miyazaki, Japan, where heating is required in winter. In order to reduce the heating energy in winter, the hot air from the attached sunspace is sent to the central air conditioning room, from where it is then distributed and stored throughout the house by way of air circulation. Only when the temperature in the sunspace exceeds 24 °C is the hot air in the sunspace sent to the central air conditioning room. The air circulation between the attached sunspace and central air conditioning room is 500 m3/h. The temperature of the attached sunspace and each room were measured. The results showed that a house with a sunspace can save about 12.2% of energy compared to a house without a sunspace.
Experimental Analysis of the Thermal Performance of a Sunspace Attached to a House with a Central Air Conditioning System
In this paper, the thermal performance of a sunspace attached to a house with a central air conditioning system was experimentally investigated. The house with a south-facing sunspace is located in Miyazaki, Japan, where heating is required in winter. In order to reduce the heating energy in winter, the hot air from the attached sunspace is sent to the central air conditioning room, from where it is then distributed and stored throughout the house by way of air circulation. Only when the temperature in the sunspace exceeds 24 °C is the hot air in the sunspace sent to the central air conditioning room. The air circulation between the attached sunspace and central air conditioning room is 500 m3/h. The temperature of the attached sunspace and each room were measured. The results showed that a house with a sunspace can save about 12.2% of energy compared to a house without a sunspace.
Experimental Analysis of the Thermal Performance of a Sunspace Attached to a House with a Central Air Conditioning System
Qingsong Ma (author) / Hiroatsu Fukuda (author) / Myonghyang Lee (author) / Takumi Kobatake (author) / Yuko Kuma (author) / Akihito Ozaki (author) / Xindong Wei (author)
2018
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
Analysis of thermal performance of building attached sunspace
Online Contents | 2011
|Thermal simulation of an attached sunspace and its experimental validation
Tema Archive | 2007
|The Solar Village in Dalby - Evaluation of an Energy-Efficient Row House with Attached Sunspace
British Library Conference Proceedings | 1993
|Optimization Design of Courtyard Sunspace Passive Solar House
Trans Tech Publications | 2012
|