A platform for research: civil engineering, architecture and urbanism
Power Quality Analysis by H-Bridge DSTATCOM Control by Icosθ and ESRF SOGI-FLL Methods for Different Industrial Loads
This work develops the analysis of power quality by the H-bridge Static Distribution Compensator (DSTATCOM) as well as its control techniques in different industry-based loading conditions. The function of DSTATCOM is to diminish power quality problems arising due to commercial as well as industrial loads. For reference current extraction, the novel Icosθ and proposed enhanced SRF SOGI-FLL (synchronous reference frame second-order generalized integrator frequency-locked loop) controller have been adopted in the H-bridge DSTATCOM. The Icosθ controller’s performance is dependent on the in-phase and quadrature-phase angle, which changes accordingly as load changes, whereas the proposed enhanced SRF SOGI-FLL controller works in synchronization with the grid with an inverter. The two control techniques were compared in terms of balancing, power factor improvement, DC-link voltage control, and harmonic minimization. The harmonics minimization of the proposed controller has been validated by IEEE 519 standards. The extracted reference currents are fed to the hysteresis current controller for the generation of pulses toward the inverter switches of DSTATCOM. The DSTATCOM system along with control algorithms have been tested on various loading conditions, i.e., voltage source- and current source-based non-linear loads, induction heating-based loads, and electric arc furnace. The complete DSTATCOM systems were implemented and executed in the MATLAB/Simulink platform and then power quality improvement features were investigated.
Power Quality Analysis by H-Bridge DSTATCOM Control by Icosθ and ESRF SOGI-FLL Methods for Different Industrial Loads
This work develops the analysis of power quality by the H-bridge Static Distribution Compensator (DSTATCOM) as well as its control techniques in different industry-based loading conditions. The function of DSTATCOM is to diminish power quality problems arising due to commercial as well as industrial loads. For reference current extraction, the novel Icosθ and proposed enhanced SRF SOGI-FLL (synchronous reference frame second-order generalized integrator frequency-locked loop) controller have been adopted in the H-bridge DSTATCOM. The Icosθ controller’s performance is dependent on the in-phase and quadrature-phase angle, which changes accordingly as load changes, whereas the proposed enhanced SRF SOGI-FLL controller works in synchronization with the grid with an inverter. The two control techniques were compared in terms of balancing, power factor improvement, DC-link voltage control, and harmonic minimization. The harmonics minimization of the proposed controller has been validated by IEEE 519 standards. The extracted reference currents are fed to the hysteresis current controller for the generation of pulses toward the inverter switches of DSTATCOM. The DSTATCOM system along with control algorithms have been tested on various loading conditions, i.e., voltage source- and current source-based non-linear loads, induction heating-based loads, and electric arc furnace. The complete DSTATCOM systems were implemented and executed in the MATLAB/Simulink platform and then power quality improvement features were investigated.
Power Quality Analysis by H-Bridge DSTATCOM Control by Icosθ and ESRF SOGI-FLL Methods for Different Industrial Loads
Srikanth Islavatu (author) / Pradeep Kumar (author) / Amit Kumar (author) / Surender Reddy Salkuti (author)
2022
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
SOGI–FLL Based Adaptive Filter for DSTATCOM Under Variable Supply Frequency
Springer Verlag | 2016
|VEREINSNACHRICHTEN - COMMUNICATIONS - SOGI
Online Contents | 2009
VEREINSNACHRICHTEN - COMMUNICATIONS - SOGI
Online Contents | 2004
VEREINSNACHRICHTEN - COMMUNICATIONS - SOGI
Online Contents | 2006
VEREINSNACHRICHTEN COMMUNICATIONS - SOGI
Online Contents | 2009