A platform for research: civil engineering, architecture and urbanism
Specifics of Building Envelope Air Leakage Problems and Airtightness Measurements
In addition to transmission heat loses the infiltration of outdoor air can cause significant heat losses. The external building envelope should be airtight in order to prevent uncontrolled cold air infiltration. The article analysis modern building materials and structures influence on airtightness. The practical measurements of renovated buildings’ airtightness are presented and compared to non-renovated buildings. In addition paper presents data on airtightness measurements of whole multi apartment building and single apartment in analyzed building taking inco accout properties of building materials. The airtightness of single apartment was evaluated with support pressure in neighbor apartments. The results show that the airtightness measurements of multi apartment building can be evaluated by measuring single apartment on last floor with support pressure in neighbor apartments. The practical measurement of renovated buildings had shown the air leakage rate q50 of typical Latvian construction after renovation is between 2.5 and 2.9 m3/(m2·h). Since the building envelope has to minimize the heat loses (transmission and infiltration) and ventilation system either mechanical or natural has to provide necessary air exchange, the building envelope airtightness shouldn’t be dependent on type of ventilation systems.
Specifics of Building Envelope Air Leakage Problems and Airtightness Measurements
In addition to transmission heat loses the infiltration of outdoor air can cause significant heat losses. The external building envelope should be airtight in order to prevent uncontrolled cold air infiltration. The article analysis modern building materials and structures influence on airtightness. The practical measurements of renovated buildings’ airtightness are presented and compared to non-renovated buildings. In addition paper presents data on airtightness measurements of whole multi apartment building and single apartment in analyzed building taking inco accout properties of building materials. The airtightness of single apartment was evaluated with support pressure in neighbor apartments. The results show that the airtightness measurements of multi apartment building can be evaluated by measuring single apartment on last floor with support pressure in neighbor apartments. The practical measurement of renovated buildings had shown the air leakage rate q50 of typical Latvian construction after renovation is between 2.5 and 2.9 m3/(m2·h). Since the building envelope has to minimize the heat loses (transmission and infiltration) and ventilation system either mechanical or natural has to provide necessary air exchange, the building envelope airtightness shouldn’t be dependent on type of ventilation systems.
Specifics of Building Envelope Air Leakage Problems and Airtightness Measurements
Borodinecs Anatolijs (author) / Nazarova Jekaterina (author) / Zajacs Aleksandrs (author) / Malyshev Alexandr (author) / Pronin Vladimir (author)
2016
Article (Journal)
Electronic Resource
Unknown
Metadata by DOAJ is licensed under CC BY-SA 1.0
IMPACT OF AIR LEAKAGE ON THE BUILDING ENVELOPE: MYTHS AND FACTS ABOUT AIRTIGHTNESS
British Library Online Contents | 2011
|Unsteady pressurization method to measure the airtightness of the building envelope
British Library Conference Proceedings | 2003
|Building air leakage characteristics and airtightness durability of single-family dwelling
DOAJ | 2023
|Simulation of the Impact of Commercial Building Envelope Airtightness on Building Energy Utilization
British Library Online Contents | 2007
|