Tests on 120-ft-span prestressed concrete beam
Tests to destruction of 120-ft-span prestressed concrete beam similar to beams to be used in 4-span overpass at Chiswick, Great Britain; at ultimate load beam failed by crushing of concrete in top flange at deflection of 20 in.; calculated ultimate load was 6% less than actual failing load; assumptions for ultimate load calculations were vindicated.
Tests on 120-ft-span prestressed concrete beam
Tests to destruction of 120-ft-span prestressed concrete beam similar to beams to be used in 4-span overpass at Chiswick, Great Britain; at ultimate load beam failed by crushing of concrete in top flange at deflection of 20 in.; calculated ultimate load was 6% less than actual failing load; assumptions for ultimate load calculations were vindicated.
Tests on 120-ft-span prestressed concrete beam
ASCE -- Proc (J Structural Div)
Base, G.D. (author) / Rowe, R.E. (author)
1960
26 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Tests on a 120-ft Span Prestressed Concrete Beam
ASCE | 2021
|Test on 55-ft. Span prestressed concrete beam
Engineering Index Backfile | 1955
|Two-span Haunched continuous beam is prestressed concrete
Engineering Index Backfile | 1960
|Multi-span prestressed concrete continuous beam bridge dismantling method
European Patent Office | 2023
|Large-span prestressed concrete frame beam hinge joint structure
European Patent Office | 2021
|