A platform for research: civil engineering, architecture and urbanism
Performance of magnesium galvanic anodes in underground service
Tests at Midland, Mich, and Freeport, Tex; experience data from different soils presented; factors affecting anode performance, including anode composition and impurities, anode current density, time, backfill composition, and backfill preparation and installation practice; of anode compositions tested, high purity Mg -- 6% Al -- 3% Zn alloy exhibits best performance.
Performance of magnesium galvanic anodes in underground service
Tests at Midland, Mich, and Freeport, Tex; experience data from different soils presented; factors affecting anode performance, including anode composition and impurities, anode current density, time, backfill composition, and backfill preparation and installation practice; of anode compositions tested, high purity Mg -- 6% Al -- 3% Zn alloy exhibits best performance.
Performance of magnesium galvanic anodes in underground service
Corrosion
Osborn, O. (author) / Robinson, H.A. (author)
Corrosion ; 8