Concrete arch dam, 100 m high, 200 m long, forms reservoir of 150 million cu m; data on stress analysis, expansion joints, intake and gallery; four Francis turbines develop 18,000 hp each; alternators of 17,000 kva, 10,000 v; single phase transformers of 10,000 kva, 10/130 kv; measurement of deformations.
Concrete arch dam, 100 m high, 200 m long, forms reservoir of 150 million cu m; data on stress analysis, expansion joints, intake and gallery; four Francis turbines develop 18,000 hp each; alternators of 17,000 kva, 10,000 v; single phase transformers of 10,000 kva, 10/130 kv; measurement of deformations.
Le barrage de Castillon
Le barrage de Castillon
Ehrmann, P. (author)
1949
41 pages
4 Supp Plates, Photographs, Schematic Drawings