Use of convolution integrals for calculating temperature of cooling strata surrounding newly created, dry, deep mine roadway has been successfully applied to British mine after reversal of ventilation which made it into intake sufficiently close to downcast shaft to be considerably affected by seasonal changes in air temperature; although nothing was known initially of thermal properties of strata surrounding roadway, methods of making rough initial estimates of their values were obtained; predictions of rise in temperature have been made for 1150 yd of intake airway at mine.
Use of convolution integrals for calculating temperature of cooling strata surrounding newly created, dry, deep mine roadway has been successfully applied to British mine after reversal of ventilation which made it into intake sufficiently close to downcast shaft to be considerably affected by seasonal changes in air temperature; although nothing was known initially of thermal properties of strata surrounding roadway, methods of making rough initial estimates of their values were obtained; predictions of rise in temperature have been made for 1150 yd of intake airway at mine.
Air temperature along main intake roadway
Colliery Guardian
Jones, C. (author)
Colliery Guardian ; 208
1964
7 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Air temperatures along instantaneously created roadway
Engineering Index Backfile | 1964
|Heat flow into new main roadway
Engineering Index Backfile | 1958
|Design and construction of main roadway junctions underground
Engineering Index Backfile | 1960
|Design and construction of main roadway junctions underground
Engineering Index Backfile | 1961
|DEVICE FOR WATER INTAKE, CLEANING AND DISCHARGE FROM BRIDGE ROADWAY
European Patent Office | 2020
|