A platform for research: civil engineering, architecture and urbanism
Asbestos-cement pipe for water mains and sewers
Review of physical properties of asbestos cement pipe, its resistance to corrosion, methods of constructing water mains and sewers with it, its strength and water-tightness, its friction coefficients and its cost; results of leakage tests; factor of safety; value of Kutter's coefficient "n" for sewer pipe; safe loads for asbestos cement sewer pipe in trench.
Asbestos-cement pipe for water mains and sewers
Review of physical properties of asbestos cement pipe, its resistance to corrosion, methods of constructing water mains and sewers with it, its strength and water-tightness, its friction coefficients and its cost; results of leakage tests; factor of safety; value of Kutter's coefficient "n" for sewer pipe; safe loads for asbestos cement sewer pipe in trench.
Asbestos-cement pipe for water mains and sewers
Boston Soc Civ Engrs -- J
Hyland, W.L. (author)
1941