Cathodic protection of lead cables in urban area
Steps in establishing cathodic protection system for lead covered telephone cables in Chicago area; system arrangements discussed include distributed ground beds, forced current through drainage system, distributed negative connections to several underground cables, and duct anodes; how to prevent damage to surrounding underground plants in installation and use of these systems.
Cathodic protection of lead cables in urban area
Steps in establishing cathodic protection system for lead covered telephone cables in Chicago area; system arrangements discussed include distributed ground beds, forced current through drainage system, distributed negative connections to several underground cables, and duct anodes; how to prevent damage to surrounding underground plants in installation and use of these systems.
Cathodic protection of lead cables in urban area
Corrosion
Plym, L.M. (author)
Corrosion ; 12
1956
5 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.