Over 200 concrete mixes of different composition were tested with various methods of measuring consistency; European versions of penetration test, slump test, flow test and remolding test were used; consistency was evaluated by appearance; test methods and results are presented; formulas are developed for prediction of water need of concrete as function of test method, consistency, cement content and aggregate grading; direct and indirect comparisons are shown to check reliability of new formulas.
Over 200 concrete mixes of different composition were tested with various methods of measuring consistency; European versions of penetration test, slump test, flow test and remolding test were used; consistency was evaluated by appearance; test methods and results are presented; formulas are developed for prediction of water need of concrete as function of test method, consistency, cement content and aggregate grading; direct and indirect comparisons are shown to check reliability of new formulas.
Concrete consistency and its prediction
RILEM Bul
Popovics, S. (author)
1966
18 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Vibration Consistency Prediction Model for Roller-Compacted Concrete
Online Contents | 2003
|Vibration Consistency Prediction Model for Roller-Compacted Concrete
British Library Online Contents | 2003
|Measuring consistency of concrete
Engineering Index Backfile | 1964
|Engineering Index Backfile | 1895
Consistency and time in mixing concrete
Engineering Index Backfile | 1912
|