A platform for research: civil engineering, architecture and urbanism
Measurement of concrete strength by embedded pullout bars
Results of laboratory investigation in which 120 pull-out specimens and 120 cylinders were cast from 30 batches of concrete; mixes and test ages were varied over usable ranges; uncrushed and crushed gravels were used as coarse aggregate; coefficient of variation of pull-out tests was only slightly greater than that of compressive strength tests; high degree of correlation exists between two tests.
Measurement of concrete strength by embedded pullout bars
Results of laboratory investigation in which 120 pull-out specimens and 120 cylinders were cast from 30 batches of concrete; mixes and test ages were varied over usable ranges; uncrushed and crushed gravels were used as coarse aggregate; coefficient of variation of pull-out tests was only slightly greater than that of compressive strength tests; high degree of correlation exists between two tests.
Measurement of concrete strength by embedded pullout bars
Am Soc Testing Matls -- Preprint
Tremper, B. (author)
American Society for Testing Materials -- Meeting ; 1944
1944
8 pages
Conference paper
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Measurement of concrete strength by embedded pullout bars
Engineering Index Backfile | 1944
|PULLOUT TESTS OF NSM - FRP BARS IN CONCRETE
British Library Conference Proceedings | 2005
|