A platform for research: civil engineering, architecture and urbanism
Model experiments for design of sixty-inch water tunnel
Application of guide vane cascade to elbows in proposed 60-in. water tunnel at David Taylor Model Basin; experimental determination of hydrodynamic performance of resulting cascade of vanes; checking final cascade in elbow of model water tunnel to determine correlation between model and prototype and checking suitability of proposed vanes with regard to stresses, deflection, and vibrations.
Model experiments for design of sixty-inch water tunnel
Application of guide vane cascade to elbows in proposed 60-in. water tunnel at David Taylor Model Basin; experimental determination of hydrodynamic performance of resulting cascade of vanes; checking final cascade in elbow of model water tunnel to determine correlation between model and prototype and checking suitability of proposed vanes with regard to stresses, deflection, and vibrations.
Model experiments for design of sixty-inch water tunnel
Minn Univ -- St Anthony Falls Hydraulic Laboratory -- Project Report
1948
80 pages
Illustrations, Diagrams, Charts
Report
English