Spillway and outlet works Shelbyville dam, Kaskaskia river, Illinois
Tests were conducted on 1 to 40 scale model reproducing spillway for Shelbyville Dam, combination concrete and earth structure rising 108 ft above bed of river; flow conditions in approach, discharge characteristics of spillway, hydrostatic pressures on ogee weir crest, performance of conventional stilling basin, and height of training walls were investigated; satisfactory energy dissipation was obtained with 125 ft long horizontal stilling basin; model indicated that height of stilling basin training walls could be reduced 5 ft.
Spillway and outlet works Shelbyville dam, Kaskaskia river, Illinois
Tests were conducted on 1 to 40 scale model reproducing spillway for Shelbyville Dam, combination concrete and earth structure rising 108 ft above bed of river; flow conditions in approach, discharge characteristics of spillway, hydrostatic pressures on ogee weir crest, performance of conventional stilling basin, and height of training walls were investigated; satisfactory energy dissipation was obtained with 125 ft long horizontal stilling basin; model indicated that height of stilling basin training walls could be reduced 5 ft.
Spillway and outlet works Shelbyville dam, Kaskaskia river, Illinois
U S Waterways Experiment Station -- Tech Report
Bucci, D.R. (author) / Grace, Jr., J.L. (author)
1966
133 pages
Report
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Carlyle Dam, Kaskaskia River, Illinois
NTIS | 1961
|Evaluation of spiral-blade concrete mixer, shelbyville reservoir project, shelbyville, illinois
Engineering Index Backfile | 1968
|Lake Blalock Spillway and Outlet Works Improvements
British Library Conference Proceedings | 1999
|