Results of series of physical and chemical tests of ten commercial tar or bitumen preparations, used to coat concrete surfaces exposed to corrosive action; some of these materials gave effective protection against 5 per cent sulphuric acid or 20 per cent acetic acid acting for 7 days; proposed standards for such coatings.
Results of series of physical and chemical tests of ten commercial tar or bitumen preparations, used to coat concrete surfaces exposed to corrosive action; some of these materials gave effective protection against 5 per cent sulphuric acid or 20 per cent acetic acid acting for 7 days; proposed standards for such coatings.
Testing coatings used to protect concrete surfaces
Ueber die Prufung und ein Prufverfahren von Betonschutzanstrichen
Tonindustrie-Zeitung ; 51
1927
7 pages
3 Figs.