A platform for research: civil engineering, architecture and urbanism
Tests of laced compression members of the old warnow bridge at Niex
Methods and results of tests of full size struts and posts, 7 to 9.6 m. long, of obsolete weld steel bridge built in 1886; details of behavior of members under buckling stresses, particularly at point of failure.
Tests of laced compression members of the old warnow bridge at Niex
Methods and results of tests of full size struts and posts, 7 to 9.6 m. long, of obsolete weld steel bridge built in 1886; details of behavior of members under buckling stresses, particularly at point of failure.
Tests of laced compression members of the old warnow bridge at Niex
Versuche mit gegliederten Druckstaben der aus-gebauten Warnowbrucke bei Niex
Bierrett, G. (author)
Bauingenieur ; 8
1927
9 pages
18 Figs.
Article (Journal)
German
© Metadata Copyright Elsevier B. V. All rights reserved.
Global Buckling of Frames with Laced Compression Members
British Library Conference Proceedings | 2016
|